3.2 Combustible Finish

3.2.1 Trim Installation
NOTE: It is not required to use the #KZK-052 discharge trim (#KZK-
052DT) if desired to run finishing material up to the finishing material
standoff. Finishing material must not block the opening and must be
run evenly along the plenum opening.
WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct
system is installed in accordance to this manual AND the convection
baffle is removed when using these combustible clearances.
Drywall stops at nishing material stando s
around KZK discharge opening. The discharge
trim covers these edges completely.
Combustible
material
Discharge trim
2
(67mm)
Figure 3.2, Drywall Finish
Up to 1" (25mm) thick combustible material up to the edge
of dicharge trim. 1" (25mm) combustible material cannot
go closer to discharge opening.
1" (25mm) combustible material goes on top of any
required non-combustible material on the fireplace.
Combustible
material up to
1" (25mm) thick
Discharge trim
4
(124mm)
Figure 3.3, Combustible Finish Material up to 1" Thick
Komfort Zone Kit #KZK-052 R.1
"
"
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Non-combustible materials, such as tile or stone,
up to the air discharge opening. Minimum air discharge
opening must be maintained the length of the air
discharge opening.
Discharge trim is optional for this installation.
Non-combustible material
up to discharge opening
¾
2
(70mm)
Figure 3.4, Non-combustible Material Trim Finish
"
FACING AND FINISHING 11