KOMFORT ZONE KIT
#KZK-045
For use with the Bellingham-44
Direct Vent Gas Fireplace
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
1.0 INTRODUCTION .......................................................................3
1.1 Kit Contents.......................................................................................... 3
1.2 Fireplace Preparation ........................................................................ 3
1.3 Suggested Configurations .............................................................. 4
1.4 Dimensions and Overview ............................................................. 5
1.5 Air Duct Run ......................................................................................... 6
2.0 FRAMING AND CLEARANCES ................................................7
2.1 Clearance to Sprinkler ...................................................................... 7
2.2 Framing.................................................................................................. 8
2.3 #KZK-045 Clearances ........................................................................ 9
3.0 FACING AND FINISHING .......................................................10
3.1 Non-combustible Requirements ................................................10
3.2 Combustible Finish ..........................................................................11
3.3 Hearth and Mantel Clearances ....................................................13
4.0 INSTALLATION .......................................................................14
Hussong Manufacturing Co., Inc.
P.O. Box 577, 204 Industrial Park Drive
Lakefield, MN 56150-0577, USA
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
HUSSONG MANUFACTURING CO., INC.
READ ALL THESE STEPS
BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE
APPLIANCE.
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of
the heater installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the appliance.
Please read the appliance owner's manual
completely before performing any procedures in
these instructions.
This optional convection duct kit redistributes the
warm air flow away from the fireplace opening to
a more desirable location using natural convection
without the use of a fan. The warm air flow may be
relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room. The result
is much cooler wall temperatures above the fire-
place opening for locating televisions, artwork, etc.
Rev. 1, 8/20

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Kozy Heat Fireplaces KZK-045

  • Page 1: Table Des Matières

    2.1 Clearance to Sprinkler ..............7 is much cooler wall temperatures above the fire- 2.2 Framing....................8 place opening for locating televisions, artwork, etc. 2.3 #KZK-045 Clearances ................ 9 3.0 FACING AND FINISHING ............10 3.1 Non-combustible Requirements ..........10 3.2 Combustible Finish ................11 3.3 Hearth and Mantel Clearances ............13...
  • Page 3: Introduction

    Figure 1.1, #KZK-045 #KZK-410-6 Figure 1.3, Stand-off Assembly Installation (4) - 10’ x 6” (aluminum ex) listed to UL-181Class 0 Air Duct Figure 1.2, #KZK-410-6 Komfort Zone Kit #KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 3...
  • Page 4: Suggested Configurations

    1.3 Suggested Configurations #KZK-045 front wall outlet #KZK-045 rear wall outlet #KZK-045 corner installation Figure 1.4, #KZK-045 Suggested Configurations 4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-045 R.1...
  • Page 5: Dimensions And Overview

    ½ ” (38mm) ¾ ” (19mm) stando stando 6” ¼ ¾ ¼ 4” ” ” ” (152mm) (101mm) (210mm) (425mm) (210mm) Figure 1.5, #KZK-045 Dimensions Komfort Zone Kit #KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 5...
  • Page 6: Air Duct Run

    WHEN INSTALLING AIR DUCT PIPE MAINTAIN A MINIMUM 4" VERTICAL RISE FOR EVERY 12" HORIZONTAL RUN Minimum bend radius=6” (152mm) 4” (102mm) 12” (304mm) Figure 1.6, Minimum Vent Pipe Run 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-045 R.1...
  • Page 7: Framing And Clearances

    60” min (1524mm) ½ ” min Ceiling sprinkler head (89mm) Figure 2.1, KZK Clearance to Sprinkler Komfort Zone Kit #KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 7...
  • Page 8: Framing

    ½ ” (2197mm) ¼ ” (2039mm) Plenum support 22” (559mm) Dimensions re ect minimum replace enclosure height Figure 2.2, #KZK-045 Plenum and BHM-44 Rough Opening Ceiling/Fireplace enclosure top Ceiling/Fireplace enclosure top ½ ” Double horizontal (1537mm) header TV Recess ¼...
  • Page 9: Kzk-045 Clearances

    (1464mm) (559mm) The combustible KZK support framing is the only combustible framing support allowed within the enclosure Figure 2.5, #KZK-045 and BHM-44 Framed Opening and Clearances Komfort Zone Kit #KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 9...
  • Page 10: Facing And Finishing

    ” (1148mm) ⁄ ” (633mm) ½ ” (1130mm) ½ ” (63mm) Non-combustible material only Combustible material allowed Figure 3.1, Minimum Non-combustible Finishing Dimensions 10 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-045 R.1...
  • Page 11: Combustible Finish

    Discharge trim is optional for this installation. NOTE: It is not required to use the #KZK-045 discharge trim (#KZK- 045DT) if desired to run finishing material up to the finishing material standoff. Finishing material must not block the opening and must be run evenly along the plenum opening.
  • Page 12 Non-combustible material Finishing edge Figure 3.5, #KZK-045 Combustible Wall Finish 12 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-045 R.1...
  • Page 13: Hearth And Mantel Clearances

    6” (152mm) Top nishing edge 25” (635mm) ½ ” (699mm) ½ ” Bottom (64mm) nishing edge 14” (356mm) Figure 3.6, Hearth and Mantel Clearances Komfort Zone Kit #KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 13...
  • Page 14: Installation

    24 inches. Install the #KZK-045DT discharge trim to the plenum, after the wall finish is completed, using (2) screws if using the #KZK-045 plenum. Finishing material must not block opening and should run evenly along plenum opening. The #KZK-045DT discharge trim is optional depending on finishing material choice.
  • Page 16 KIT KOMFORT ZONE nº KZK-045 Pour utiliser avec le foyer au gaz à évacuation HUSSONG MANUFACTURING CO., INC. directe Bellingham 44 nº BHM-44 INSTALLATEUR : Laissez ce manuel avec l’appareil. PROPRIÉTAIRE : Conservez ce manuel pour le consulter. English and French installation manuals are available through your LISEZ TOUTES CES ÉTAPES...
  • Page 18: Introduction

    ⁄ ” (122mm) (4) collets de xation (fournis) Figure 1.1, Plénum, collets et garniture de sortie du kit no KZK-045 KZK-410-6 Figure 1.3, Installation des étriers de dégagement (4) - section de 10 pieds x 6 po conduit exible (aluminium) homolgué...
  • Page 19: Configurations Suggérées

    1.3 Configurations suggérées KZK-045 sortie mural avant KZK-045 sortie mural avant KZK-045 installations dan un coin Figure 1.4, Configurations suggérées du KZK-045 4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-045 R.1...
  • Page 20: Dimensions Et Vue D'ensemble

    ” (19mm) dégagement espaceur de 6” ¼ ¾ ¼ 4” ” ” ” dégagement (152mm) (101mm) (210mm) (425mm) (210mm) Figure 1.5, Dimensions du KZK-045 Kit Komfort Zone nº KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 5...
  • Page 21: Installation Des Conduit D'air

    LES CONDUITS D’AIR DOIVENT ÊTRE INSTALLÉS AVEC UNE ÉLÉVATION VERTICALE MINIMALE DE 4 PO (10 CM) À TOUS LES 12 PO (30 CM) DE COURSE HORIZONTALE 4” (102mm) 12” (304mm) Figure 1.6, Installation de conduits d'air de longueur minimale 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-045 R.1...
  • Page 22: Encadrement Et Dégagements

    à votre installation. 60” min (1524mm) ½ ” min Tête de gicleur au plafond (89mm) Figure 2.1, Dégagement au gicleur du kit KZK Kit Komfort Zone nº KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 7...
  • Page 23: Encadrement

    ” (108mm) 88” (2235mm) 88” ⁄ ” (2235mm) ¼ ” (1463mm) (1175mm) 22” ¼ ” (558mm) (1175mm) Figure 2.3, Encadrement et dégagement 8 ENCADREMENT ET DÉGAGEMENTS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-045 R.1...
  • Page 24: Dégagements D'encadrement

    Le support d'encadrement combustible de KZK est le seul support d’encadrement combustible autorisé à l'intérieur de l'enceinte Figure 2.5, Dégagements et dimensions minimum d'encadrement de plénum Kit Komfort Zone nº KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 9...
  • Page 25: Façade Et Finition

    (633mm) ½ ” (1130mm) ½ ” (63mm) Matériaux incombustibles Matériaux combustible seulement permis Figure 3.1, Dimensions minimales des matériaux incombustibles de finition 10 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-045 R.1...
  • Page 26: Matériaux De Finition Combustibles

    NOTE: Il n’est pas obligatoire d’utiliser la garniture de sortie d’air du kit KZK-045, si vous désirez installer les matériaux de finition jusqu’aux Matériau espaceurs de dégagement des matériaux de finition. Les matériaux de Combustible finition ne doivent pas boucher l’ouverture de sortie d’air du plénum,...
  • Page 27 être installée par dessus le panneau de ciment Matériau incombustible Bord de nition du foyer Figure 3.5, Matériaux de finition murale combustibles avec le KZK-045 12 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-045 R.1...
  • Page 28: Dégagements De L'âtre Et Du Manteau

    (635mm) ½ ” (699mm) ½ ” Bord de nition (64mm) du foyer 14” (356mm) Figure 3.6, Dégagements de l’âtre et du manteau Kit Komfort Zone nº KZK-045 R.1 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 13...
  • Page 29: Installation

    NOTE: Les brides de fixation ne sont pas conçues pour supporter le poids du plénum et des conduits. Installez des 14 INSTALLATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-045 R.1...
  • Page 30 Après avoir terminé l’installation des matériaux de finition murale, fixez au plénum la garniture de sortie d’air du KZK-045, en utilisant (2) vis si vous utilisez le plénum du kit KZK-045. Les matériaux de finition ne doivent pas boucher l’ouverture de sortie d’air du plénum, mais doivent border uniformément tout...

Table des Matières