1.0 INTRODUCTION .......................................................................3
1.1 Kit Contents.......................................................................................... 3
1.2 Suggested Configurations .............................................................. 4
1.3 Dimensions and Overview ............................................................. 5
1.4 Air Duct Pipe Run ............................................................................... 6
2.0 FRAMING AND CLEARANCES ................................................7
2.1 Clearance to Sprinkler ...................................................................... 7
2.2 Framing.................................................................................................. 8
2.3 Minimum Shelf Requirements ...................................................... 9
3.0 FACING AND FINISHING .......................................................10
3.1 Non-combustible Requirements ................................................10
3.2 Combustible Finish ..........................................................................11
3.3 Hearth and Mantel Clearances ....................................................13
4.0 INSTALLATION .......................................................................16
Hussong Manufacturing Co., Inc.
P.O. Box 577, 204 Industrial Park Drive
Lakefield, MN 56150-0577, USA
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
HUSSONG MANUFACTURING CO., INC.
READ ALL THESE STEPS
BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE
APPLIANCE.
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of
the heater installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the appliance.
Please read the appliance owner's manual
completely before performing any procedures in
these instructions.
This optional convection duct kit redistributes the
warm air flow away from the fireplace opening to
a more desirable location using natural convection
without the use of a fan. The warm air flow may be
relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room. The result
is much cooler wall temperatures above the fire-
place opening for locating televisions, artwork, etc.
The use of this kit will permit lower mantel clear-
ances to be used. These lower mantel clear-
ances must be only used when the KZK Duct
system is installed.
Rev. 1

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Kozy Heat Fireplaces KZK-1510

  • Page 1: Table Des Matières

    KOMFORT ZONE KIT #KZK-1510 For use with the Callaway-72 #CLW-72 HUSSONG MANUFACTURING CO., INC. Direct Vent Gas Fireplace INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. English and French installation manuals are available through your READ ALL THESE STEPS local dealer.
  • Page 3: Introduction

    KZK-CPL6 is (6) 6" couplers that connect (2) KZK-610 #KZK-1510 (6) take o collars included Figure 1.1, #KZK-1510 #KZK-610 (6) - 10’ x 6” (aluminum ex) listed to UL-181Class 0 Air Duct Figure 1.2, #KZK-610 Komfort Zone Kit #KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 4: Suggested Configurations

    1.2 Suggested Configurations When installing the #KZK-1510, take in consideration the fireplace venting and the plenum tube configuration. #KZK-1510 SIDE WALL OUTLET #KZK-1510 REAR WALL OUTLET Figure 1.3, #KZK-1510 Suggested Configurations Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510...
  • Page 5: Dimensions And Overview

    If you are mounting the plenum above the fireplace between 10’ (3m) to 20’ (6m) you will need (2) #KZK-610 kit and #KZK-CPL6 coupler kit. Figure 1.5, KZK-1510 Overview Komfort Zone Kit #KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 6: Air Duct Pipe Run

    WHEN INSTALLING AIR DUCT PIPE MAINTAIN A MINIMUM 4" VERTICAL RISE FOR EVERY 12" HORIZONTAL RUN MINIMUM BEND RADIUS=6” 4” 12” Figure 1.6, Minimum Vent Pipe Run Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510...
  • Page 7: Framing And Clearances

    Please follow local building codes to determine what temperature setting is relevant for your installation. 60” MIN ½ CEILING SPRINKLER HEAD ” MIN Figure 2.1, KZK Clearance to Sprinkler Komfort Zone Kit #KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 8: Framing

    ” Figure 2.2, Minimum Clearances from Air Discharge to Ceiling ¼ 17” 17” ” (431mm) ¼ ” (260mm) ¼ ” (1708mm) 22” Figure 2.3, Rough Opening and Framing Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510...
  • Page 9: Minimum Shelf Requirements

    (457mm) (457mm) 81” 79” (2057mm) (2007mm) 3” (76mm) 18” GRILLE (457mm) 3” (76mm) 18” (457mm) 81” 79” (2057mm) (2007mm) ENCLOSURE FLOOR ENCLOSURE FLOOR Figure 2.4, Minimum Shelf Requirements Komfort Zone Kit #KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 10: Facing And Finishing

    NO SCREWS ALLOWED COMBUSTIBLE MATERIAL ALLOWED NO SCREWS ALLOWED NO SCREWS ALLOWED ¾ ” ¾ ” 13” 13” (95mm) (330mm) (95mm) (330mm) Figure 3.2, Minimum Non-combustible Finishing Dimensions Screw Locations Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510...
  • Page 11: Combustible Finish

    OF ANY REQUIRED NON-COMBUSTIBLE MATERIAL REQUIRED ON THE FIREPLACE COMBUSTBILE ⁄ ” MATERIAL UP TO 1” THICK DISCHARGE GRILLE ⁄ ” ⁄ ” Figure 3.4, #KZK-1510 Combustible Finishing Material up to 1" Thick Komfort Zone Kit #KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 12 KZK air discharge grille. COMBUSTIBLE WALL FINISH UP TO 1” (25mm) THICK MAY BE INSTALLED OVER CEMENT BOARD FINISHING EDGE FIREPLACE ENCLOSURE FLOOR Figure 3.5, KZK-1510 Combustible Wall Finish Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510...
  • Page 13: Hearth And Mantel Clearances

    FINISHING EDGE ⁄ ” ⁄ ” (467mm) (715mm) FINISHING EDGE 14” (356mm) 17” (432mm) ½ ” (248mm) 20” (508mm) Figure 3.6, Hearth and Mantel Clearances for No Surround Komfort Zone Kit #KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 14 EDGE OF SURROUND ⁄ ” (600mm) ⁄ ” (784mm) EDGE OF SURROUND 14” (356mm) ¼ ” 17” (432mm) (184mm) 20” (508mm) Figure 3.8, Hearth and Mantel Clearances for CW72-GS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510...
  • Page 15 EDGE OF SURROUND ⁄ ” (600mm) ⁄ ” (784mm) EDGE OF SURROUND 14” (356mm) ¼ ” 17” (432mm) (184mm) 20” (508mm) Figure 3.10, Hearth and Mantel Clearances for CW72-RS4 Komfort Zone Kit #KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 16: Installation

    Support horizontal sections every pages). Fix the plenum to the framing using nails or screw 24 inches. through the top mounting bracket. Continue with fireplace installation. Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510...
  • Page 18 KIT KOMFORT ZONE nº KZK-1510 Pour utiliser avec le foyer au gaz à évacuation HUSSONG MANUFACTURING CO., INC. directe Callaway-72 nº CLW-72 INSTALLATEUR : Laissez ce manuel avec l’appareil. PROPRIÉTAIRE : Conservez ce manuel pour le consulter. English and French installation manuals are available through your LISEZ TOUTES CES ÉTAPES...
  • Page 20: Introduction

    1.0 INTRODUCTION 1.1 Contenu du Kit • (2) plénum de 72 po du kit KZK-1510 • (2) grilles d'air • (12) collets de 6 po - (6) collets à fixer au bas du plénum; (6) collets à fixer au foyer, à l'endroit où les couvercles sont retirés (1) KZK-610 est utilisé...
  • Page 21: Configurations Suggérées

    1.2 Configurations suggérées KZK-1510 SORTIE MURALE ADJACENT KZK-1510 SORTIE MURALE ARRIÈRE Figure 1.3, Configurations suggérées du KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510...
  • Page 22: Dimensions Et Vue D'ensemble

    Si vous installez le plénum à plus de 10 pieds (3 m) et moins de 20 pieds (6 m) au-dessus du foyer, vous aurez besoin de deux (2) kits nº KZK-610 et du kit de coupleurs nº KZK-CPL6. Figure 1.5, Vue d'ensemble du kit KZK-1510 Kit Komfort Zone nº KZK-1510...
  • Page 23: Installation Des Conduit D'air

    LES CONDUITS D’AIR DOIVENT ÊTRE INSTALLÉS AVEC UNE ÉLÉVATION VERTICALE MINIMALE DE 4 PO (10 CM) À TOUS LES 12 PO (30 CM) DE COURSE HORIZONTALE RAYON DE COURBURE MINIMAL=6” 4” 12” Figure 1.6, Installation de conduits d'air de longueur minimale Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510...
  • Page 24: Encadrement Et Dégagements

    Veuillez suivre les codes du bâtiment locaux pour déterminer quel réglage de température convient à votre installation. 60” MIN ½ TÊTE DE GICLEUR AU PLAFOND ” MIN Figure 2.1, Dégagement au gicleur du kit KZK Kit Komfort Zone nº KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 25: Encadrement

    Figure 2.2, Dégagement minimal de la sortie d'air au plafond ¼ 17” 17” ” (431mm) ¼ ” (260mm) ¼ ” (1708mm) 22” Figure 2.3, Encadrement et dégagement Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510...
  • Page 26: Dimensions Minimales D'installation Et Exigences Avec Étagère

    (2007mm) 3” (76mm) 18” GRILLE D’AIR (457mm) 3” (76mm) 18” (457mm) 81” 79” (2057mm) (2007mm) PLANCHER DE L'ENCEINTE PLANCHER DE L'ENCEINTE Figure 2.4, Requis d'une tablette d'étagère Kit Komfort Zone nº KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 27: Façade Et Finition

    AUCUNE VIS PERMISE ¾ ” ¾ ” 13” 13” (95mm) (95mm) (330mm) (330mm) Figure 3.2, Emplacements de vis permis (pour matériaux incombustibles de finition de dimensions minimales Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510...
  • Page 28: Matériaux De Finition Combustibles

    MATÉRIAU COMBUSTIBLE JUSQU'À 1 POUCE ⁄ D'ÉPAISSEUR ” GRILLE D'ÉVACUATION D'AIR ⁄ ” ⁄ ” Figure 3.4, Matériaux de finition combustibles de 1 po d'épaisseur maximale Kit Komfort Zone nº KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 29: Matériaux De Finition Murale Combustibles

    être installée par dessus le panneau de ciment. BORD DE FINITION DU FOYER PLANCHER D’ENCEINTE DU FOYER Figure 3.5, Matériaux de finition murale combustibles avec le KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510...
  • Page 30: Dégagements De L'âtre Et Du Manteau

    BORD DE FINITION DU FOYER 14” (356mm) 17” (432mm) ½ ” (248mm) 20” (508mm) Figure 3.6, Dégagements de l’âtre et du manteau pour une installation sans contour Kit Komfort Zone nº KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 31 (600mm) ⁄ ” (784mm) BORD DU CONTOUR 14” (356mm) ¼ ” 17” (432mm) (184mm) 20” (508mm) Figure 3.8, Dégagements de l’âtre et du manteau pour le CW72-GS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510...
  • Page 32 (600mm) ⁄ ” (784mm) BORD DU CONTOUR 14” (356mm) ¼ ” 17” (432mm) (184mm) 20” (508mm) Figure 3.10, Dégagements de l’âtre et du manteau pour le CW72-RS4 Kit Komfort Zone nº KZK-1510 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 33: Installation

    Installez le(s) plénum(s) dans l’ouverture brute encadrée, tout l’air chaud. Supportez les sections de conduit horizontales à tous en maintenant les dégagements minimums aux matériaux les 24 pouces (60 cm). Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510...