Hearth And Mantel Clearances - Kozy Heat Fireplaces KZK-054 Mode D'emploi

Masquer les pouces Voir aussi pour KZK-054:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3 Hearth and Mantel Clearances

The following drawings show the hearth and mantel clearances
allowed for the CLW-50 and CLW-ST with no surround or optional
surrounds installed. The CLW-50 and CLW-ST use the same optional
surrounds. Follow the drawings for the minimum distance needed
between the hearth and mantel when installing an optional surround
to allow for proper servicing clearances.
Surround Edge
Finishing Trim Edge
Figure 3.10, Finishing Guidelines for Optional Surrounds for CLW-50 & CLW-ST
Figure 3.11, CLW-50 Hearth and Mantel Clearances for No Surround
Komfort Zone Kit #KZK-054 R.5
B
Non-Combustible Zone
Combustible wall nish
may be installed over non-combustible
material and butt up to the nshing
edge around the opening
Each square represents
1" (25mm) of projection
Non-combustible
material
12" (305mm)
9" (229mm)
6" (152mm)
Finishing Edge
¾
16
"
(425mm)
½
26
"
(673mm)
Finishing Edge
6" (152mm)
9" (229mm)
¾
9
"
(248mm)
12" (305mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
3.3.1 Finishing Guidelines for Optional Surrounds
Figure 3.10 shows where to end finishing materials, when
measuring from the finishing edge, to allow installation of any
optional surround. Most finishing material will not fit behind the
optional surround(s) when it is installed.
Measurement 'A' shows the space to leave on each side.
Measurement 'B' shows the space to leave on the top and the
bottom.
Surround
CW50-RS
A
CW50-RS4
CW50-GS
CW50-FS
CLW-50
No surround
½
" (13mm) clearance
around pipe
Steel
Framing
Fireplace Enclosure Floor
A
B
3/4" (19mm)
3/4" (19mm)
2-5/8" (66mm)
2-5/8" (66mm)
6" (152mm)
2-1/2" (64mm)
3-1/8" (79mm)
3-1/8" (79mm)
FACING AND FINISHING 19

Publicité

Chapitres

Table des Matières
loading

Table des Matières