3.2.3 CLW-ST Combustible Wall Finish
Figure 3.9 shows installation of combustible wall finish up to 1"
thick. This combustible material goes over any required non-
combustible materials as shown in Figure 3.3 on page 15.
This 1" (25mm) combustible material is able to go down to the
fireplace finishing edge.
See Figure 3.6 on page 16 for up to 1" (25mm) thick
combustible material installation around the discharge trim of
the KZK air discharge opening.
Non-combustible zone
Combustible wall nish
up to 1" (25mm) thick
may be installed over
required non-combustible
material up to the top
nishing edge and the
bottom of the air
discharge opening
Finishing
edge
Non-combustible
material only
Figure 3.9, #KZK-054 Combustible Wall Finish for CLW-ST
18 FACING AND FINISHING
CLW-ST
17"
(432mm)
Combustible wall nish
up to 1" (25mm) thick
may be installed over
76"
required non-combustible
(1930mm)
material up to the top
bottom of the air
discharge opening
Finishing
edge
Non-combustible
material only
Fireplace enclosure oor
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
nishing edge and the
Komfort Zone Kit #KZK-054 R.5