3.2 Combustible Finish

3.2.1 Finishing Material

NOTE: If you desire to run finishing material up to edge of the discharge
opening, see Figure 3.3 and Figure 3.4 below. Finishing material must
not block the air discharge grille and must be run evenly along the
plenum opening.
WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct
system is installed in accordance to this manual AND the convection
baffle is removed when using these combustible clearances.
DRYWALL STOPS AT EDGE OF AIR DISCHARGE OPENING.
AIR GRILLE DISCHARGE WILL OVERLAP EDGES OF DRYWALL
¼
10
"
(260mm)
Figure 3.3, #KZK-1510 Drywall Finish
UP TO 1" (25mm) THICK COMBUSTIBLE MATERIAL UP TO EDGE OF
THE AIR DISCHARGE GRILLE. 1" COMBUSTIBLE MATTERIAL CANNOT GO
CLOSER TO DISCHARGE OPENING. 1" COMBUSTIBLE MATERIAL GOES ON TOP
OF ANY REQUIRED NON-COMBUSTIBLE MATERIAL REQUIRED ON THE FIREPLACE
11
"
Figure 3.4, #KZK-1510 Combustible Finishing Material up to 1" Thick