Kozy Heat Fireplaces KZK-054 Mode D'emploi page 22

Masquer les pouces Voir aussi pour KZK-054:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.
CLW-50: Remove (4) cover plates on top of the appliance (4
screws each). See Figure 4.5.
CLW-ST: Remove (4) cover plates on top of the appliance (4
screws each). See Figure 4.6.
Figure 4.5, CLW-50 Cover Plate Removal
Figure 4.6, CLW-ST Cover Plate Removal
3.
Align the take off collars to the corresponding holes on top of
the appliance. Secure with screws previously removed. Install
the take off collars to the corresponding opening(s) on the
plenum(s). Use supplied screws.
4.
Frame a rough opening at the desired location. See previous
pages of this manual for allowable plenum positions and rough
frame opening sizes.
5.
Install the plenum into the rough frame opening maintaining
minimum clearances to combustibles as listed (see previous
pages). Fix the plenum to the framing using nails or screw
through the top mounting bracket.
NOTE: Mounting brackets are not intended to carry the weight
of the plenum and pipes. Provide support to the underside of
the plenum and ensure the plenum is level and its outlet is not
distorted.
6.
Use metal strapping (all-around, not supplied) as required to
further secure the plenum to framing.
22 INSTALLATION
7.
Attach the piping from all (4) plenum take off collars to all (4)
take off collars on the fireplace. If you are mounting the plenum
10' or less above the fireplace, use (1) #KZK-410-6 kit or UL-181
Class 0 approved air duct. If you are mounting the plenum
between 10' to 20' above the fireplace then you will need (2)
#KZK-410-6 kits and #KZK-CPL6 or UL-181 Class 0 approved air
duct.
8.
An upward slope must be maintained in horizontal sections of
pipes for proper convection. Support horizontal sections every
24 inches.
9.
Install the #KZK-054DT discharge trim to the plenum after the
wall finish is completed using (2) screws, if using the #KZK-054
plenum. Finishing material must not block and should run
evenly along plenum opening. The #KZK-054DT discharge trim is
optional depending on finishing material choice.
10. Continue with fireplace installation.
Figure 4.7, Trim Installation
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Komfort Zone Kit #KZK-054 R.5