3.2 Combustible Finish
NOTE: It is not required to use the #KZK-050 discharge trim if desired to
run finishing material up to the finishing material standoff. Finishing
material must not block the opening and must be run evenly along the
plenum opening.
WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct
system is installed in accordance to this manual AND the convection
baffle is removed when using these combustible clearances.
NOTE: THESE MANTEL CLEARANCES APPLY ONLY WHEN THE KZK DUCT SYSTEM
COMBUSTIBLE WALL FINISH
MAY BE INSTALLED OVER CEMENT
BOARD AND BUTT UP TO THE
FINISHING EDGE AROUND THE OPENING
EACH SQUARE REPRESENTS
OF MANTEL PROJECTION
(673mm)
¾
9
"
(248mm)
Figure 3.3, KZK-050 Mantel Clearances
10
IS INSTALLED AND THE CONVECTION BAFFLE REMOVED.
1" (25mm)
12" (305mm)
9" (229mm)
6" (152mm)
FINISHING EDGE
¾
16
"
(425mm)
½
26
"
FINISHING EDGE
6" (152mm)
9" (229mm)
12" (305mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
STEEL
FRAMING
FIREPLACE ENCLOSURE FLOOR
Komfort Zone Kit #KZK-158 R.3