4.0 INSTALLATION

The Kozy Zone Kit requires that the convection baffle(s), located
above the firebox inside the appliance metal cabinet, to be removed
to allow the hot airflow to convect upwards into the air ducts
installed on the fireplace.
1.
Remove the convection baffle(s) from the appliance.
CLW-50: The baffle is secured by (2) screws right behind the
upper edge of the fireplace opening. See Figure 4.3.
CLW-ST: The (6) baffles are secured by (2) screws each behind the
upper edge of both fireplace openings. See Figure 4.4.
Recycle this panel as it is no longer needed.
Instructions continue on the next page.
Take-o collar
Convection
ba e to be
removed
Convection air ow
with ba e in place
Figure 4.1, CLW-50 Air Flow with Convection Baffle Removed
Convection air ow with ba es removed
Figure 4.2, CLW-ST Air Flow inside Appliance with Convection Baffles Removed
Komfort Zone Kit #KZK-054 R.5
Figure 4.3, CLW-50 Convection Baffle Removed
Convection air ow
with ba e removed
Figure 4.4, CLW-ST Convection Baffles Removal - 1 Side
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
INSTALLATION 21