Technical specifications
Voltage:
Frequency / protection
type:
Max. heating power:
Heating levels:
Input:
Fan power:
Weight app.
Article No.
Transport and storing
The appliance may be transported using the handle and
transport wheels.
Store any appliances not used in a dry and locked
room.
Assembly (pic. 2, 3)
Step 1
Using the supplied screws, mount the chassis to both sides of
the electric heater. Make sure the wheel axis holes are on the
fan side.
Step 2
Put the wheel axis through appropriate holes in the mounted
chassis and secure it using the supplied pins. Now screw on
the transport wheels.
Step 3
Mount the travel handle to the upper part of the mounted
chassis.
Operation
The appliance may be put into operation after reading and
understanding the general safety instructions and
appliance-specific safety instructions. In doing so, proceed
as follows:
To reach the optimum heat distribution, put the electric heater
in the middle of the room or at least 1 m from the wall, if
possible. Air will circulate better this way and the room will get
warmer faster. All windows and doors must be closed.
Connection
Put the extension cable appropriate for this purpose to
the electric heater plug and plug the appliance.
Provide appropriate protection of your electrical network.
Operation
Using the thermostat regulator, adjust the required
switch-off temperature.
The function switch has 5 switch levels:
0
= off
= ventilation
= heating power 1/3
= heating power 2/3
= heating power 3/3
GH 15 E electric heater
400 V
50 Hz/IP 4
15 kW (12.900 kcal./h)
7,5/15 kW
22 A
3
900 m
per hour
2
kg
85106
To switch the electric heater off, let the function button in the
"Ventilation" position for app. 3-5 minutes (depending on the
model). The appliance can then be switched off or unplugged.
Never unplug the appliance when hot, let it cool down
first. The fan may still ventilate after being switched off.
Thermostat setting
Set the thermostat to the average switch-off
temperature.
Set the fan to the full heating power and let it heat until
the thermostat switches off.
Switch the fan off and measure the room temperature.
If the room temperature is too low, turn the thermostat
regulator more to the right and switch the fan on again.
If the room temperature is too high, turn the thermostat
more to the left, let the room cool down and switch the
fan on again.
Keep repeating these steps until reaching the required
temperature.
Attention: For the first commissioning of the electrical
heater, it can sometimes be an unpleasant odor which
is completely harmless and completely disappears with
increasing operating time.
10