Maintenance Table
Maintenance periods are valid for normal operating conditions; in case of
extreme operating conditions the maintenance periods are shortened correspondingly.
Actions
Intake suction filter check
• cleaning
• replacement
Cleaning of reverse valve and insert
Oil level check
Oil replacement
1. replacement of mineral oil
of synthetic oil
Filling up/adding the oil
Draining the condensation water from air
receiver
Draining the condensation water from
pressure reducing valve of the filter
Filter insert cleaning
Compressor cleaning
Screwing check
EU DECLARATION OF CONFORMITY
We,
Güde GmbH & Co. KG
Birkichstrasse 6
D-74549 Wolpertshausen
Germany,
herewith declare that the following machine complies with the appropriate basic safety and healthy requirements of the EU Directives
based on its design and type, as brought into circulation by us.
In case of alternation of the machine, not agreed upon by us, this declaration will lose its validity.
Machine description:
COMPRESSOR 210/08/24
Article No.:
#50010
Applicable EU Directives:
2006/42/EG
2006/95/EG
2004/108/EG
Applicable harmonised standards:
EN 1012-1:1996
EN 60204-1:2006
EN 55014-1:2006
EN 55014-2/A1:2001
EN 61000-3-2:2006
EN 61000-3-11:2000
Noise:
Lwa:
92 dB
Lpa:
85 dB
Date/authorised signature:
Title of signatory:
Technical documentation:
Periods
Weekly every
50 hours of operation,
min. once a year
Yearly
Daily or more precisely before
every putting into operation
after 50 hours of operation
once a year
every two years
As required
After every use
After every use
As required
As required
First time after 10 hrs. of
operation, subsequently every
500 hrs. of operation
July 1st, 2010