Careful compressor maintenance
It is necessary to follow the lubrication
instructions (see the throat for oil adding and oil
level inspection in the "Handling" chapter).
It is necessary to follow instructions concerning
protective cover in the air filter described in the
"Handling" chapter.
Check regularly the power cord. If damaged it needs
to be repaired or replaced in the service repair
centre. Make sure there is no outer visible damage
of the compressor. In case of need, please contact
the nearest repair centre.
Outdoor use
If use the compressor outside it is allowed to use
extension cables designed for outdoor use and with
appropriate marking only.
Attention: It is necessary to use a cable with
sufficient cross section (min. of 1.5 mm
cables longer than 10 m there may be starting
problems at unfavourable temperatures.
Attention
Work considerately and use common sense. Do not
use the compressor if you are tired, impaired or
intoxicated with drugs causing tiredness.
Check faulty and untight construction parts
If there has been any damage to any protective
device or other constructional elements it is
necessary to check the compressor before restarting
in order to ensure its safe operation.
All damaged constructional elements need to be
repaired in the customer service centre or replaced
as described in the operating instructions of the
device.
Correct compressor using
Follow all instructions mentioned in these operating
instructions at operating the compressor. Prevent
children or persons not familiarised with the manner
of working of the compressor from using it.
Keep the cowl screen clean
Keep the engine cowl screen clean. Clean the
screen regularly if you operate the compressor in an
environment with severe pollution.
Operate the compressor at rated voltage
Operate the compressor at voltage specified on the
type label. If the compressor is operated at voltage
higher than the specified rated voltage inadmissible
engine overheating may occur.
Do not let the device running unattended
Do not use the compressor when faulty
If there are any strange sounds, strong vibrations at
the compressor or it seems to be faulty in other way
it needs to be stopped immediately. Have the reason
identified at the nearest repair centre.
Do not clean the plastic parts with solvents
Solvents, such as petrol, thinners, engine oil or other
substances containing alcohol, may damage the
plastic parts of the machine. Therefore do not clean
those parts with such substances but use soap suds
or other – suitable liquids instead.
Use original spare parts only
When using spare parts of other manufacturers
claim arising from the guarantee expires and
compressor working failures may occur. Original
spare parts are available at authorised dealers.
Do not make any alterations to the compressor
Do not make any alterations to the compressor. If the
compressor needs to be repaired please contact the
customer service centre. Any non-approved alteration may
negatively influence the compressor output; it may also
cause serious injuries if made by persons without necessary
technical skills.
Do not touch any hot compressor parts
Do not touch any cables, engine or other constructional
elements of the compressor in order not to get burnt.
Never keep the device switched on unattended, it could
become source of danger.
If you execute repairs or service of safety or protective
devices of the machine these parts must be immediately
reassembled after works are finished.
It is necessary to know both regulations for prevention of
injuries valid at the place of device using and generally
2
accepted safety rules.
); at
Safety device functioning needs to be checked before using
the device. Make sure functioning of parts with seemingly
slight damage is really all right.
Unless otherwise provided in these operating instructions,
the damaged parts and safety devices need to be repaired
or replaced in an authorised service centre.
Have the damaged switches replaced in an authorised
service centre.
This device corresponds to all appropriate safety regulations.
Repairs may only be executed by qualified electricians in
authorised service repair centres while using original spare
parts. Failing to observe this regulation may lead to an
accident.
Behaving in Case of Emergency
Provide first aid corresponding to seriousness of injuries and seek
qualified medical advice as soon as possible. Put the injured
person to peace and protect him/her against other injuries.
Device Use as Designed
For blowing and works with compressed air, in clay-modelling, for
airbrush painting of walls, airbrush varnishing works, tyre
pressure rating, etc.
Residual Dangers
Direct electric contact
A faulty cable or faulty connector plug may lead to a fatal
accident caused by electric current.
Have always the faulty cables and connector plugs replaced at a
specialist. Use the device at a connector equipped with current
protector (RCD) only.
Indirect electric contact
Injury by parts of the machine that are live or by faulty
constructional elements of the machine.
Always pull the connector plug out of socket at maintenance
works. Operate with current protector only.
Insufficient local lighting
Insufficient lighting represents a high safety risk.
Always ensure sufficient lighting at work with this device.
Disposal
Instructions for disposal result from icons on the device, or more
precisely, on the package. Description of each meaning can be
found in the "Marking" chapter.