4.2.a - Discharging condensation
When condensation in the lower tray reaches the predetermined level, the appliance emits beeps.
in this case:
a. disconnect the plug from the power socket.
b. Carefully move the appliance in position suitable to unload water.
c. remove the drain cap (24) and the rubber cap (24a) (fig.22).
Make sure you correctly tightened the drain cap (24) in order to avoid water leak.
d. make water unload completely.
e. reposition the rubber cap (24a) and screw the drain cap (24) (fig.23).
f. insert the plug in the power socket.
If the error repeats, please contact an Assistance Centre.
4.2.b - Error codes
during the appliance functioning, a few anomalies which stop its functioning could appear.
in these cases, some error codes appear on the control panel.
• P1 lower tray full.
-------------------------------------------------------------------
• F1 filters cleaning.
-------------------------------------------------------------------
• E1 • E2 • E3 • E4
in these cases:
a. electrically disconnect the appliance
b. wait a few minutes
c. connect the plug to the power socket
d. restart the appliance.
If the inconvenience persists and the error code doesn't turn off, electrically disconnect the
appliance and refer to an Assistance Centre.
5 - TECHNICAL DATA
for the technical data, please consult the data plate applied to the product (fig.2).
• Dimensions (W x H x D)
• Weight (without packing)
• Maximum operating temperature
in cooling mode
• Minimum operating temperature
in cooling mode
* internal ambient temp.
** outside ambient temp.
EN - 28
345 x 703 x 355 mm
24 Kg
dB 35°C - WB 24°C * / dB 43°C - WB 32°C **
17°C * / 16°C **