4.1.c - Recommendations for energy saving
Below find simple recommendations for reducing consumption:
• Always and constantly keep the filters clean (see maintenance and cleaning chapter).
• Keep the doors and windows of the rooms to be climate controlled closed.
• Do not let sun rays penetrate freely into the room (we recommend using curtains or lowering blinds or
closing the shutters).
• Do not obstruct the air flow path (input and output) of the appliance; this, in addition to obtaining a non-op-
timal yield, also affects the correct operation of the appliance and the possibility of irreparable damages to
the appliance itself.
4.2 - MAINTENANCE
If you do not intend to use the appliance for a long period of time, work as follows:
a. Activate the fan only mode for a few hours (approximately 1÷2 hours) to dry the interior of the appliance.
b. Stop the air conditioner and disconnect the power supply.
c. Clean the air filter.
d. Completely discharge condensation.
e. Remove the batteries from the remote control.
f. Place the appliance in its original packaging and store it in a fresh and dry environment, away from direct
exposure to sunlight.
Do not store the appliance in moist or particularly dirty environments.
Checks before resuming use of the air conditioner:
a. Clean the filters after a long period of inactivity of the air conditioner.
b. Check that the air outlet or inlet are not obstructed (especially after a long period of inactivity of the air
conditioner).
4.2.a - Discharging condensation
When condensation water in the lower tray reaches the predetermined level, the appliance emits a beep
and the LED (S9) lights up.
In this case:
a. Disconnect the plug from the power socket.
b. Carefully move the appliance in position suitable to unload water.
c. Remove the drain cap (24) and the rubber cap (24a) (Fig.17).
Make sure you correctly tightened the drain cap (24) in order to avoid water leak.
d. Make water unload completely.
e. Reposition the rubber cap (24a) and screw the drain cap (24) (Fig.18).
f. Insert the plug in the power socket.
If the error repeats, please contact an Assistance Centre.
5 - TECHNICAL DATA
For the technical data, please consult the data plate applied to the product (Fig.2).
EN - 25
DOLCECLIMA ARIA 8