EU Declaration of Conformity
We,
Güde GmbH & Co. KG
Birkichstraße 6
74549 Wolpertshausen
Germany
hereby declare the conception and construction of the below-mentioned appliances correspond - at the type of construction being
launched - to appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us the Declaration expires.
Marking of appliances:
Order No.:
Date/producer signature:
Signed by:
Technische Dokumentation:
Appropriate EU Directives:
2004/108/EG
2006/42/EG
Harmonised standards used:
EN 609-1/A2:2009
EN 61000-3-3:1995+A1+A2
EN 61000-3-2:2006
EN 55014-2:1997+A1
EN 55014-1:2006
Noise level:
Lwa: 85,2 dB
Lpa: 69,9 dB
Troubleshooting
Problems
Possible causes
1. No current in the outlet
2. Defective extension cable
Engine not starting
3. Wrong feeder cable
4. Defective switch, condenser
Wrong engine running
1. Wrong connection
direction
1. Two-hand switching lever adjustment
Splitting knife not moving
1.
2.
3.
Splitter has no power
4.
5.
After being pressed, the
1. Defective fuse, etc.
green switching button not
2. 2 phase running
staying in place
1.
Hydraulic pump whistling;
splitting knife running jerky
2.
DHH 1250/12 T
01962
07.03.2012
Managing Director
Mr. Arnold
J. Bürkle FBL; QS
Wrong rotation direction
Too little hydraulic oil
Starting rod is bent; the hydraulic
lifter is not pressed to the full extent
Wood with too many knots - splitting
knife gets jammed
Operating arm is bent
Oil loss, surface is dirty
Too little hydraulic oil in the tank
Remedy
1. Check the network protection
2. Pull out the plug – check it and replace it if necessary
3. Connection with 5 cores with a cross section of 2.5 mm
4. Have the appliance checked by an electrician
1. Turn the phase changer in the appliance plug using a
screwdriver
1.  Check the oil level
 Defective control valve must be replaced in a service
centre only
1. Change the rotation direction
2. Add hydraulic oil
3.  Check all screws on the starting rod
 Adjust the pull rod (pic. 10/B); by this,
 the hydraulic lifter will be pressed to the full extent.
4. Lubricate the splitting knife with fat.
5. Return the operating arm to the starting position.
1. Check the cable
1.  Tighten the screwing
 Replace the hoses
2. Add hydraulic oil
13