Installation instructions
CA
12
(EN)
Requirements for alcove or closet installation
Your dryer is approved for installation in an alcove or closet (as specified on the dryer back).
When installing a dryer in a closet alcove it MUST be exhausted to the outdoors. No
other fuel burning appliance can be installed in the same closet or alcove.
The total ventilation area must be a minimum of 60 sq. in. (387 cm
distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of
120 sq. in. (774 cm
louvered door with the minimum air opening is acceptable). Minimum installation clearances are
required but more clearance is recommended.
1" (25 mm)
WARNING!
2
) of open area equally distributed. The openings must never be obstructed (a
1" (25 mm)
1" (25 mm)
) of open area equally
2
min 2" (50 mm)
min 1" (25 mm)
(rear of product to wall)
Fig.4 Minimum clearances
total ventilation area
120 in.sq (774 cm )
Fig.5 Minimum ventilation
minimum clearance
required
56 ⁄ " (1430 mm)