Mount the sensor near the centerline and close to the bottom of
the transom.
Route the sensor cable over the transom, through a drain hole, or
through a hole that you have drilled in the transom above the
waterline.
1. Place the sensor against the hull and mark the position of the
screw holes with a pencil.
2. Using a 3mm or 1/8" drill bit, drill pilot holes at the marked
locations, 10mm (3/8") deep.
3. Apply marine sealant to the threads of the purchased screws
to prevent water from seeping into the transom.
4. Screw the temperature sensor to the hull.
5. If a hole must be drilled through the transom, choose a
location well above the waterline. Check for obstructions
such as trim tabs, pumps, or wiring inside the hull. Mark the
location with a pencil. Drill a hole through the transom using
the appropriate size hole saw or spade bit (to accommodate
the connector). Do NOT remove the connector.
6. Route the cable over or through the transom.
7. On the outside of the hull, secure the cable against the
transom using a purchased cable clamp(s). Mark the position
of the screw hole(s) with a pencil.
8. Using a 3mm or 1/8" drill bit, drill a pilot hole(s) at the marked
locations, 10mm (3/8") deep.
9. Apply marine sealant to the threads of the screw(s) to prevent
water from seeping into the transom.
10.Fasten the cable clamp(s) in place.
11.If a hole has been drilled through the transom, apply marine
sealant to the space around the cable leading through the
transom.
4
ANNEXE 3 INSTALLATION DES CAPTEURS DE TEMPÉRATURE
Cable Routing & Connecting
1. Route the cable to the instrument, being careful not to tear the
2. Refer to the instrument owner's manual to connect the sensor
Replacement Sensor & Parts
The information needed to order a replacement sensor is printed
on the cable tag. Do not remove this tag. When ordering, specify
the part number and date. For convenient reference, record this
information at the top of page one.
Obtain parts from your instrument manufacturer or marine dealer.
Gemeco
(
U
S
Airmar EMEA
(Europe, Middle East, Africa) Fax:
35 Meadowbrook Drive, Milford, New Hampshire 03055-4613, USA
Copyright © 2014 Airmar Technology Corp. All rights reserved.
AP-12
cable jacket when passing it through the bulkhead(s) and other
parts of the boat. To reduce electrical interference, separate
the sensor cable from other electrical wiring and sources of
noise. Coil any excess cable and secure it in place with cable
ties to prevent damage.
to the instrument.
Tel:
) A
F
a
: x
email:
Tel:
email:
• www.airmar.com
803-693-0777
8
0
3
6 -
9
3
0 -
4
7
7
sales@gemeco.com
+33.(0)2.23.52.06.48
+33.(0)2.23.52.06.49
sales@airmar-emea.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fcv-588

Table des Matières