Télécharger Imprimer la page

Symbols Used; Safety Instructions; Operating Instructions - Truma S 2200 Mode D'emploi

Chauffage au gaz liquéfié pour les caravanes et autres remorques
Masquer les pouces Voir aussi pour S 2200:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
S 2200 / S 2200 P Liquid gas heater for caravans and other trailers
Table of contents

Symbols used ...................................................................... 13

Safety instructions .......................................................... 13

Important operating notes ............................................. 14
Intended use ........................................................................ 14
Heating system S 2200 / S 2200 P ............................... 15
Start-up .............................................................................. 15
S 2200 P with Piezo ignitor ................................................. 15
S 2200 with auto ignitor ...................................................... 15
Switching off .................................................................... 15
Maintenance ..................................................................... 15
Auto ignitor battery change ................................................ 16
Cleaning .............................................................................. 16
Disposal ............................................................................. 16
Technical data ................................................................... 16
Dimensions ......................................................................... 16
Declaration of conformity .............................................. 17
Truma Manufacturer's Warranty ................................... 17
Intended use ........................................................................ 18
Regulations ....................................................................... 18
Selecting a location ......................................................... 18
Exhaust duct via the roof cowl ........................................... 18
side wall .............................................................................. 18
Heater installation ........................................................... 18
the side wall (cowl kit AKW2) .......................................... 19
Drill holes for wall cowl ....................................................... 19
Duct connection to the heater ............................................ 19
Fitting the exhaust and air intake duct ............................... 19
Exhaust duct via the roof (AKD cowl kit) ....................... 20
Combustion air intake installation ....................................... 20
Installing the roof cowl ........................................................ 20
Exhaust pipe assembly ....................................................... 20
Attaching the heater ....................................................... 20
Warm air distribution ...................................................... 20
Gas connection ................................................................. 20
Function test ..................................................................... 21
Warnings ............................................................................. 21
Symbols used
Symbol indicates a possible hazard.
Risk of burns! Hot surfaces.
Wear protective gloves to prevent possible mechanical
injuries.
Note containing information and tips.
Safety instructions
An open roof window / skylight in the area of the roof cowl
holds the risk of entry of exhaust gas into the vehicle interior.
The heater may only be operated when the roof window / sky-
light is closed.
The use of upright gas cylinders from which gas is extracted
in the gas phase is mandatory when gas regulators, gas
equipment and gas systems are being operated. Gas cylinders
from which gas is taken in the liquid phase (e. g. for fork lifts)
must not be used, since they would result in damage to the
gas system.
If the gas system is leaking or if there is a smell of gas:
- Extinguish all naked flames
- Do not smoke
- Switch off gas appliances
- Close gas cylinder
- Open windows and doors
- Do not operate any electric switches
- Have the entire system inspected by an expert!
Repairs may only be carried out by an expert.
A new O-ring must be fitted whenever the exhaust duct has
been removed!
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
- Modifications to the device (including accessories)
- Modifications to the exhaust duct and the cowl
- Failure to use original Truma parts as replacement parts and
accessories
- Failure to follow the installation and operating instructions
This may also invalidate the device operating permit, which in
many countries also denotes cancellation of the vehicle oper-
ating permit.
The operating pressure of the gas supply (30 mbar) must
correspond with the operating pressure of the unit (see type
plate).
The liquid gas systems must comply with the technical and
administrative regulations of the respective country of use
(e.g. EN 1949 for vehicles). The national legislation and regu-
lations (e.g. DVGW Work Sheet G 607 in Germany) must be
observed.
Checking of the gas system must be done every 2 years by a
specialist and be validated on the test certificate (in Germany
according to DVGW Work Sheet G 607), if necessary.
13

Publicité

loading

Ce manuel est également adapté pour:

S 2200 p