installation

Electrical connection

2
Ø 4 x 2,5mm
2 x 16A
2 phases with 1 zero connection (2 1N, 380V ~ / 50Hz):
• Fit connection bridges between the connecting points 4 and 5.
The voltage between the phases and the zero is 230V and the voltage
between the phases is 400V. The fuse box in your home must be fitted
with a 16 Amp (2x) fuse. The connection cable must be minimally
2.5 mm
in diameter.
2
2 phase and 2 zero connection (2 2N, 230V ~ / 50Hz)
The voltage between the phases and the zeros is 230 V~ and the
voltage between phases is 0 V. The group must have fuses of at least
16 A (2x). The connection cable must be minimally 2.5 mm
1 phase with 1 zero connection (1 1N, 230V ~ / 50Hz):
• Fit connection bridges between the connecting points 4 and 5 and
1 and 2.
Note: connection 3 will not be used
2
Ø 3 x 6 mm
1 x 32A
2
Ø 5 x 2,5mm
2 x 16A
in diameter.
2
EN 19