Primary Filter
Start
End
12:00
8:00
8 00
pm
Set
To change the default cycle:
Start
Tap
to program the start time for the cycle.
Slide your finger up and down to roll the time scroll wheels
to adjust the start time.
End
Tap
to program the end time for the cycle.
Slide your finger up and down to roll the time scroll wheels
to adjust the end time.
Set
Tap
to save and accept the changes.
Summer Logic: In warm weather, the water temperature in the
spa may exceed the set temperature. This condition may occur
due to heat transference from the filter/circulation pump and
jets pumps. If the water temperature is higher than 35°C
(95°F) and rises two degrees above the set temperature, a
"Summer Logic" condition occurs that deactivates the fil-
ter/circulation pump and CLEARRAY®. This safety feature can-
not be altered! The filter/circulation pump and CLEARRAY®
will remain off until the water temperature cools to the set tem-
perature (except between 9am-11am when the filter/circulation
pump runs for it's mandatory 2 hour cycle.) To help prevent a
"Summer Logic" condition, it may be necessary to reduce fil-
ter/circulation pump cycles run times in warm weather.
I
Programming the Secondary Filter
To enter the Secondary Filter program, tap (
and filter menu. During a secondary filtration, the Jets Pump 1
is activated. There are 3 cycles you can select from. The fac-
tory default cycle is "Away Mode. " If you elect to keep this set-
ting, then you can skip this section.
HEAT & FILTER
>
Primary Filter
>
Secondary Filter
Indicates that the feature is active.
feature is not active.
To change the Secondary Filter cycle:
Away Mode: Secondary Filtration is disabled. To activate this
mode, tap next to the "Away" icon.
Note: This is the factory default setting.
Infrequent Mode: Activates two cycles at 8:00 PM and 8:00
AM every other day. Each cycle will last 10 minutes for a to-
tal of 20 minutes every other day. To activate this mode, tap
(
next to the "Infrequent" icon. Time and duration cannot be
)
altered.
Frequent Mode: Activates two cycles at 8:00 PM and 8:00 AM
every day. Each cycle will last 10 minutes for a total of 20 mi-
nutes every day. To activate this mode, tap (
"Frequent" icon. Time and duration cannot be altered.
>
from the heat
)
Secondary Filter
Infrequent
Frequent
Away
Indicates that the
next to the
)
48
I
Cleaup Cycle
The cleanup cycle occurs once per day at 12:00 pm (noon) for
two minutes. This is not user programmable. The Jets Pump 1
and the Circulation Pump will turn on for one minute and then
shut off. Then Jets Pump 2 will turn on and run for 1 minute
then shut off. Be aware, the factory programmed cleanup cycle
cannot be canceled or altered!
I
Blow-Out Cycle
This cycle will purge the air from the plumbing lines normally
caused by draining and filling the spa. The Jets Pump 1 and
the Circulation Pump will turn on for 1 minute and then shut
off. Then Jets Pump 2 will turn on and run for 1 minute then
shut off. This cycle will only occur:
- At start up.
- After exiting a service lock.
I
Water Care Programming
Water care is crucial to maintaining a healthy and clean spa.
The CLEARRAY water purification system leads the way by sa-
nitizing the water using a UV light bulb. Your spa can be pro-
grammed to remind you when to check and replace certain
components.
From the "Settings" menu, tap (
ter the programming options.
SETTINGS
>
Heat & Filter
>
Water Care
>
WiFi
Programming the CLEARRAY UV Bulb Timer
The CLEARRAY UV bulb has a life expectancy of 1-year. A ti-
mer activates when power is applied and begins a countdown
starting at 365 days. Once the timer expires, an error message
will appear of the display, the UV bulb must be replaced and
the timer needs to be reset.
Water Care
>
>
CLEARRAY
0 days
365
set to
Set
When you enter the "Water Care" Menu, you will able to set the
CLEARRAY UV bulb timer.
Slide your finger up and down to roll the days scroll wheel to
adjust the number of days from 0 to 365. The adjustments are
made in increments of 10 days.
Note: The CLEARRAY UV timer counts down by days not u-
sage. The days are store in memory if the power is interrup-
ted.
Note: to ensure the appliance works correctly, do not
deactivate this function; program it as specified.
>
)
next to "Water Care" to en-
Water Care
>
>
CLEARRAY
0 days
365
set to
Set
Reminder
It's time to replace your CLEARRAY bulb.
Contact your authorized dealer for replace-
ment parts.
reset
snooze