Technical Data - Camille Bauer KINAX N702 Mode D'emploi

Capteur d’inclinaison avec système de pendule amorti par huile
Masquer les pouces Voir aussi pour KINAX N702:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Features / Benefi ts
• Measuring range, sense of rotation and zero position
function programmed directly at the KINAX N702
• The output signal, representing the tilt angle, is provided
either in form of an current or voltage variation
• The transmitter is inside a robust splash-proof aluminium
case with enclosure protection IP66
• The pendulum system is oil damped
• The position of the pendulum is measured with a non
contact magnetoresistive angular position transmitter
• Pendulum shaft has no mechanical stops and can be 360°
infi nitely rotated
20
mA
15
10
5
0
90°
Layout and mode operation
Magnetoresistive inclination transmitters are extremely robust
measuring systems without a shaft stop, fully hermetically
encapsulated and capable of measuring contactless the
angular position of a permanent magnet, which is attached
to the pendulum system
oil-damped
pendulum system
axis X

Technical data

General
Measured quantity:
Measuring principle:
Pendulum damping:
Measuring input
Measuring range:
Measuring output
Output signal I
:
A
Standard range:
Load resistant:
12
180°
270°
360°
.
N
μC
S
Tilt angle α
°
Magnetoresistive angular position
transmitter, contact free, freely
rotatable without stops
With silicon oil
0 ... 360
°
Load-independent DC current,
proportional to the inclination
4...20 mA, 3-wire connection
max. 600 Ω
Power supply
Voltage supply:
18 ... 33 V DC
(no protection against wrong
polarity)
Current consumption:
< 80 mA
Accuracy
Basic accuracy:
± 0.2
Resolution:
14 bit
Transient response:
by 25° tils < 1 sec.
Additional errors (maxima)
Temperature infl uence: 0.05% / 10 K
Installation data
Housing:
Coated aluminium
Mounting position:
Any
Electrical connection:
Connector M12 x 1, 5 poles
Weight:
0.3 kg
Environmental condition
Climatic rating:
Temperature – 30° to + 70° C
Annual mean relative humidity
≤ 95%
Regulations
Test voltage:
500 Veff., 50 Hz, 1 min.
Electromagnetic
compatibility:
The standards EN 61 000-6-4 and
EN 61 000-6-2 are observed
Enclosure protection:
IP 66
Permissible vibration:
4 g, 0 ... 100 Hz
Dimensional drawings
69
3
3
4
27.2
Pin confi guration of connector
Pin assignments:
1 = 0 V
2 = + 24 V DC
4 = +20 mA
°
66.2
60.1
Ø6.4
Ø11
4
3
5
2
1

Publicité