General Declaration Of Conformity; Troubleshooting; Selve Service Hotline - Selve SEE Notice

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

General declaration of conformity/Troubleshooting

7. General declaration of conformity

SELVE GmbH & CO. KG company, hereby declares that the SEE is in conformity with
the basic requirements and other relevant provisions of the Directive 2006/42/EG and
2014/30/EU. The declaration of conformity can be looked up at www.selve.de.

8. Troubleshooting

Problem
Motor does not work
UP and DOWN directions are
switched
Motor has stopped automatically
when moving DOWN and reverses
Motor has stopped automatically
when moving UP and reverses

9. SELVE Service Hotline

• Hotline: Phone +49 2351 925-299
• Download the operating manuals
at www.selve.de or QR scan
Cause
Electric connection defective
Thermal protection switch has
triggered
End positions set incorrectly
Black and brown wire connected to
the switch incorrectly
Blockage/obstacle recognition has
triggered
Overload recognition has triggered
29
Solution
Check the connection
Wait for 5 to 20 minutes
Reset end positions
Switch wires
(black = rotation right,
brown = rotation left)
Remove obstacle, check curtain
path
Remove obstacle, check curtain
path, possibly select stronger motor
GB
GB

Publicité

Table des Matières
loading

Table des Matières