GB Reset/Technical data
5. Reset
Precondition: Both end positions must be set, this means that the drive no longer
performs a short release when reaching the lower end position.
Reset with
Reset with
switch
setting switch
1 s
E
5x 3 s with
1 s pause
6. Technical data
Series
1/10
2/7
2/10
2/15
2/20
2/30
Series 2 motors have a plug-in connection cable. Series 1 and series 3 motors have a
2.5 m mains cable as standard which is permanently installed and cannot be
replaced.
The relevant cable lengths and qualities for series 2 can be selected in the catalogue.
Connection cables must be ordered separately.
Information about connections using special connectors must be requested.
Information for all motor types:
Nominal voltage: 230 V AC/50 Hz
Safety class:
IP 44
Operating time:
4 Min.
Subject to change without prior notice!
Drive
Connect the setting switch cable to the motor
wiring cable.
Press the E button of the setting switch for
1 second. Both limit positions already set will be
deleted.
Alternatively: Move the drive upwards until it stops
automatically at the upper limit stop and performs
a short release.
Then press the switch 5 times for 3 seconds with
1 second pause in upwards direction.
Then turn on the upward direction again. The drive
moves down and switches off automatically. Now
turn off the switch.
Torque
Rotation speed
Nm
Rpm
10
7
10
15
20
30
28
Power Input
A
15
0.5
17
0.41
17
0.45
17
0.66
17
0.75
17
0.95
Output
W
115
95
105
152
172
220