5.3

MINIMUM MANTEL CLEARANCES

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
Combustible mantel clear-
ance can vary according
to the mantel depth. Use
the graph to help evaluate
the clearance needed. The
three-sided top extension
piece may be removed if
non-combustible framing is
faced with a non-combusti-
ble material.
Dashed lines are suitable mantel sizes and clearances
f i r e - p a r t s . c o m
when a non-combustible facing is used.
5.4

PENINSULA INSTALLATION

5.4.1 PENINSULA VENTING

Refer to "VENTING" section. All venting must have a minimum clearance of 2" to combustible material on the
top and 1" to the sides and bottom.

5.4.2 PENINSULA FRAMING

It is best to frame your appliance after it is positioned and the vent
system is installed. Use 2x4's and frame to local building codes.
To install the appliance face fl ush with the fi nished wall, position the
framework to accommodate the thickness of the fi nished wall.
A = 22 1/8" minus fi nishing material thickness each side.
W415-1028 / A / 08.13.12
All manuals and user guides at all-guides.com
WARNING
!
CLEARLY MAINTAINED.
HEAT RESISTANT TO PREVENT DISCOLOURATION.
73.1
11" MANTEL
7" MANTEL
11"
7"
TOP OF
APPLIANCE
32 1/2"
6 1/8"
38 5/8"
A
38 1/4"
THE UNIT IS
NOT LOAD
BEARING
2 1/2"
22 1/8"