5.10 INITIAL CONFIGURATION

Depending on the type of installation, the best con guration needs to be selected for stove operation.
Before proceeding, power up the stove.
Use the arrow buttons to scroll between the icons until reaching the setup menu
a) Use the arrow buttons
b) Use the
button to select the password "7" and then press
c) Use the
d) Press
and enter the value "54" using the
e) Press
to con rm;
f) The current con guration will be displayed;
g) To change the con guration, press
h) Press
to con rm.
seconds. Ignore this and switch the stove off using the safety switch on the rear, wait a few seconds
and switch it back on.
FOUR DIFFERENT CONFIGURATIONS ARE AVAILABLE:
CONFIGURATION 1
Set this con guration when the stove is controlled by an external thermostat (or timer thermostat).
This con guration can also be used to switch the stove on or off manually or by timer without using an external
thermostat, but rather leaving the two terminals jumpered as per the factory setting.
modulates output (to minimise fuel consumption) when reaching the set water temperature.
The stove will turn off also in case the water temperature continues to rise despite the modulation. In this case,
the stove will turn on only if the temperature difference between the value you set up and the real one is higher
than 20°C.
CONFIGURATION 2
Set this con guration to switch the stove on or off manually or by timer when the stove is connected directly to
the central heating radiators.
The stove will modulate output according to the room temperature read by the probe on the stove.
The "Eco-mode" function can be used to have the stove switch off or on based on the set room temperature.
CONFIGURATION 3
Set this con guration when wanting to connect the stove to a storage tank with coil.
The stove will be controlled (switch on and off) based on the temperature read by the probe in the storage tank.
CONFIGURATION 4
Set this con guration when wanting to connect the stove to a storage tank without coil.
The stove will switch on based on the temperature read by the probe in the storage tank, and will switch off
based on the stove return temperature.
to go to the setup menu
buttons to scroll to and select submenu
and enter the value of the new con guration using the
00 477 5220 - 14/09/2016
and then press
;
to con rm;
[30]
--0
; "
" will ash on the display;
buttons;
;
buttons;
33