Operating Instructions
8. Specifications
Specifications
Measuring ranges
Gauge pressure
Absolute pressure
Compound pressure
Pressure unit
Vacuum resistance
Fatigue life
Materials
Wetted parts
»
Pressure connection
»
Pressure sensor
Internal transmission fluid
Case
Power supply L
+
Signal output and
maximum ohmic load R
A
Response time
Current consumption
Insulation voltage
8013153/1B2T/2021-03-17
8. Specifications
Model PBT
0 bar ... 0.05 bar up to bar ... 1000 bar
0 bar ... 0.1 bar up to 0 bar ... 25 bar
–1 bar ... 0 bar up to –1 bar ... +24 bar
Bar, MPa, psi and kg/cm2
Yes
10 Mio. cycles
316 L
316 L (as of 0 ... 10 bar rel 13-8 PH)
Silicone oil (only with pressure ranges < 0 ... 10 bar and ≤ 0 ... 25 bar abs)
316 L
L
in VDC
8 ... 30
+
14 ... 30 with signal output 0 ... 10 V
R
in Ohm
4 ... 20 mA, 2-wire
A
0 ... 10 V, 3-wire
0 ... 5 V, 3-wire
{Other signal output on request}
ms
< 4
mA
Signal current (max. 25) for current output
Max. 8 for voltage output signal
2)
VDC
500
© SICK AG • Germany • All rights reserved
≤ (L
R
– 8 V) / 0.02 A
+
A
R
> 10 k
A
R
> 5 k
A
PBT
GB
25