SICK PBT Mode D'emploi page 24

Masquer les pouces Voir aussi pour PBT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Assembly of DIN EN 175301-803 L-connector
(D) Mounting hole
1. Using the head of a small screwdriver in
the mounting hole (D), lever the terminal
block (6) out of the angle housing (5).
In order not to damage the sealing of the
angle housing, do not try to push the
terminal block (6) out using the screw
hole (1) or the cable gland (2).
2. Ensure that the conductor outer diameter
you select is matched to the angle housing's cable gland. Slide the cable through the cable
gland nut (2), washer (3), gland seal (4) and angle housing (5).
Connect the flying leads to the screw terminals on the terminal block (6) in accordance
with the pin-assignment drawing.
4. Press the terminal block (6) back into the angle housing (5).
5. Tighten the cable gland (2) around the cable. Make sure that the sealing isn't damaged
and that the cable gland and seals are assembled correctly in order to ensure ingress
protection.
6. Place the flat, square gasket over the connection pins on the top of the instrument
housing.
7. Slide the terminal block (6) onto the connection pins.
8. Secure the angle housing (5) and terminal block (6) to the instrument with the screw (1).
24
7. Starting, operation
(2)
© SICK AG • Germany • All rights reserved
(1)
(3)
(5)
(4)
(6)
8013153/1B2T/2021-03-17
PBT
GB
Female
connector
Sealing
Male connector,
Case with
pressure connection
3.

Publicité

Table des Matières
loading

Table des Matières