SICK PBT Mode D'emploi page 26

Masquer les pouces Voir aussi pour PBT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Specifications
Non-linearity
4)
Accuracy
Zero offset
Hysteresis
Non-repeatability
Long-term drift
Signal noise
Permissible temperature of
Medium
Ambience
Storage
Operating temperature range
Temperature error in
operating temperature range
RoHS- conformity
Approvals
26
8. Specifications
Model PBT
2)
The power supply for the pressure transmitter must be made via an
energy-limited electrical circuit per section 9.3 of UL / EN / IEC 61010-1,
or an LPS to UL / EN / IEC 60950-1, or Class 2 per UL1310/UL1585 (NEC
or CEC). The power supply must be suitable for operation above 2,000 m
should the pressure transmitter be used at this altitude.
≤ ± 0.25 optional
% of span
≤ ± 0.5
Adjusted in vertical mounting position with lower pressure connection.
3)
Not possible with output signal 0 ... 5 V and measuring ranges ≤ 0.1 bar.
% of span
≤ ± 0.5
≤ ± 1.0
4)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
% of span
≤ 0.15 typ., ≤ 0.4 max., (with non-linearity 0.25 %)
≤ 0.5 typ., ≤ 0.8 max., (with non-linearity 0.5 %)
≤ 0.16
% of span
≤ 0.1
% of span
≤ 0.1
% of span
≤ 0.3
% of span
0 ... +80 °C
0 ... +80 °C
-20 ... +80 °C
0 ... +80 °C
≤ 1.0 typ., ≤ 2.5 max.
% of span
Yes
cULus, GOST
© SICK AG • Germany • All rights reserved
3)
(BFSL) according to IEC 61298-2
(BFSL) according to IEC 61298-2
(with non-linearity 0.25 %)
(with non-linearity 0.5 %)
according to IEC 61298-2
-30 ... +100 °C optional
-30 ... +100 °C optional
-30 ... +100 °C optional
8013153/1B2T/2021-03-17
PBT
GB

Publicité

Table des Matières
loading

Table des Matières