5. Turn off

5.1. Chemicals tank

Put the operating switch on OFF.
Pull the sucking hose out of the chemicals tank and hang it in a bucket with clean water.
Seal the chemicals tank with a cap.
Operating the machine. Rinse the hoses, gun and lance minimum 1 minute with clean water.
(Aim the gun in the free space)

5.2. Lance and gun

Uncouple the lance and put it away.
Put the operating switch on OFF.
Take the plug out of the socket.
Close the water supply.
Roll up the high and low pressure hoses.

5.3. Machine disconnect entirely

Turn off the SBH-E by means of a fuse, or by pulling the plug out of the socket. Leave the pressure out of the
hoses by means of pinching the jet pipe.
PAY ATTENTION: The frost protection is now also turned off.

5.4. Water outlet

Clean to own need the water supply.

5.5. Disconnect machine at long term

Consult a DiBO technician to put the installation long-term out of use. These can take the necessary measures
for you to let the machine stand still a longer time, without damage.

5.6. Transport

Pay attention at transport to the following:
Keeps the machine as much as possible horizontal during transport, one prevents that there leaks oil from the
pump.
Load the machine using a lift truck, hydraulic loading platform or a hoist.

5.7. Transportation at frost

Replace the water sucking hose by a short piece hose and hang it with his end in the anti-frost, so the machine
can suck the anti frost. Take the lance from the gun and operate the machine.
Tip: Because the catch of the outgoing anti frost water, this can be re-used afterwards.