14.2 Satellite band
14.2.1 Launching
Setting the remote power supply to satellite:
OFF to turn off the
remote power supply
under satellite measure
ON to turn on the
remote power
supply under
satellite measure
AUTO to launch
automatically the
remote power supply
in satellite measure
mode even after
shutting off
Configuration lines:
- OL1 frequency: OL
frequency low band of LNB
- OL2 frequency: OL frequency
high band of LNB
- OL selection: band commutation on
the LNB (22kHz, ToneBurst or DiSEqC)
- Selection polar : polarization
commutation on the LNB (13/18V
or DiSEqC)
- Switch: switch type and position
(No, ToneBurst, 22kHz, DiSEqC, Pos
A, B, C or D)
- Uncommitted: "Uncommitted" switch type
and position (No, DiSEqC, Pos 1 to 16)
- Positioner: presence of a positioner (Yes
/ No)
- SatCR: SatCR mode (single cable
distribution)
See chapter
Man-machine interface
65
for any change.
- Initialization: sets up the
OL1 and OL2 frequencies
under KU band