Format des données MIDI
La présente section explique le format des données que le M7CL peut comprendre, envoyer et
recevoir.
1 CHANNEL MESSAGE
1.1 NOTE OFF
Reception
These messages are echoed to MIDI OUT if [OTHER ECHO] is ON.
They are received if [Rx CH] matches, and used to control effects.
STATUS
1000nnnn 8n
DATA
0nnnnnnn nn
0vvvvvvv vv
1.2 NOTE ON
Reception
These messages are echoed to MIDI OUT if [OTHER ECHO] is ON.
They are received if [Rx CH] matches, and used to control effects.
STATUS
1001nnnn 9n
DATA
0nnnnnnn nn
0vvvvvvv vv
1.3 CONTROL CHANGE
Two types of control change can be transmitted and received; [NRPN] (Non-
Registered Parameter Numbers) and freely-assigned [TABLE] (1CH x 110)
messages. Select either [TABLE] or [NRPN].
Reception
These messages are echoed to MIDI OUT if [Control Change ECHO] is ON.
If [TABLE] is selected, these messages are received when [Control Change Rx] is
ON and [Rx CH] matches, and will control parameters according to the settings
of the [Control assign table]. For the parameters that can be assigned, refer to
"Paramètres pouvant être attribués à des changements de commandes" on
page 270.
If [NRPN] is selected, these messages are received when [Control Change Rx] is
ON and the [Rx CH] matches; the four messages NRPN control number (62h,
63h) and DATA ENTRY control number (06h, 26h) are used to control the
specified parameter.
Transmission
If [TABLE] is selected, and if [Control Change Tx] is ON when you operate a
parameter that is assigned in the [Control assign table], these messages will be
transmitted on the [Tx CH] channel. For the parameters that can be assigned,
refer to "Paramètres pouvant être attribués à des changements de commandes"
on page 270.
If [NRPN] is selected, and if [Control Change Tx] is ON when you operate a
specified parameter, the four messages NRPN control number (62h, 63h) and
DATA ENTRY control number (06h, 26h) are transmitted on the [Tx CH]
channel. For the parameters that can be assigned, refer to "Paramètres pouvant
être attribués à des changements de commandes" on page 270.
Control Change messages are not used for transmission to M7CL Editor because
there is no guarantee that the contents of the assignment tables will match.
(Parameter Change messages are always used.)
Control Change numbers 0 and 32 are for selecting banks.
STATUS
1011nnnn Bn
DATA
0vvvvvvv vv
STATUS
1011nnnn Bn
DATA
0vvvvvvv vv
If [TABLE] is selected
STATUS
1011nnnn Bn
DATA
0nnnnnnn nn
0vvvvvvv vv
* Numbers 0, 32, and 96–101 cannot be used.
* Control number 6, 38 can be used.
282
M7CL Mode d'emploi
Format des données MIDI
(8n)
Note off message
Note number
Velocity (ignored)
(9n)
Note on message
Note number
Velocity (1-127:on, 0:off)
(Bn)
Control change
Control number (00)
00
Control Value (0-127)
Control change
Control number (32)
20
Control Value (0-127)
Control change
Control number (1-5, 7-31, 33-37, 38-95,
102-119) *
Control Value (0-127)
Equation for converting a Control Value to parameter data
paramSteps = paramMax - paramMin + 1;
add
= paramWidth / paramSteps;
mod
= paramWidth - add * paramSteps;
curValue
= paramSteps * add + mod / 2;
(1) If the assigned parameter has fewer than 128 steps
paramWidth = 128; rxValue = Control value;
(2) If the assigned parameter has 128 or more but less than
16,384 steps
paramWidth = 16384;
(2-1) When High and Low data is received
rxValue = Control value (High) * 128 + Control value (Low);
(2-2) When only Low data is received
rxValue = (curValue & 16256) + Control value (Low);
(2-3) When only High data is received
rxValue = Control value (High) * 128 + (curValue & 127);
(3) If the assigned parameter has 16,384 or more but less than
2,097,152 steps
paramWidth = 2097152;
(3-1) When High, Middle, and Low data is received
rxValue = Control value (High) * 16384 + Control value (Middle) * 128 + Control
value (Low);
(3-2) When only Low data is received
rxValue = (curValue & 2097024) + Control value (Low);
(3-3) When only Middle data is received
rxValue = (curValue & 2080895) + Control value (Middle) * 128;
(3-4) When only High data is received
rxValue = (curValue & 16383) + Control value (High) * 16384;
(3-5) When only Middle and Low data is received
rxValue = (curValue & 2080768) + Control value (Middle) * 128 + Control value
(Low);
(3-6) When only High and Low data is received
rxValue = (curValue & 16256) + Control value (High) * 16384 + Control value (Low);
(3-7) When only High and Middle data is received
rxValue = (curValue & 127) + Control value (High) * 16384 + Control value (Middle)
* 128;
if ( rxValue > paramWidth)
rxValue = paramWidth;
param = ( rxValue - mod / 2) / add;
If [NRPN] is selected
Control change
STATUS
1011nnnn Bn
NRPN LSB
DATA
01100010 62
Parameter number LSB
0vvvvvvv vv
Control change *
STATUS
1011nnnn Bn
NRPN MSB
DATA
01100011 63
Parameter number MSB
0vvvvvvv vv
Control change *
STATUS
1011nnnn Bn
Data entry MSB
DATA
00000110 06
Parameter data MSB
0vvvvvvv vv
Control change *
STATUS
1011nnnn Bn
Data entry LSB
DATA
00100110 26
Parameter data LSB
0vvvvvvv vv
* The STATUS byte of the second and subsequent messages need not
be added during transmission. Reception must occur correctly
whether or not the status byte is omitted.