Valve outlet
Union nut M20 x 1.5 (H.20)
Recommended tightening torque
3 – 5 Nm for union nut
M20 x 1.5 (G.13, H.20)
Operating temperature
-20 °C to +50 °C
Product ID number
CE-0085BQ0102
DG approval number: 3894
Subject to technical changes.
Installation instructions
The unit may only
be installed and
repaired by an
expert. Read the
installation in-
structions carefully before
working, and then comply
with them!
Disregarding installation
instructions or erroneous
installation can put people in
danger and cause damage to
property.
Safety instructions
– Residual gas: No smoking, no
naked flames!
– In order to ensure that the
equipment operates correctly,
the gas pressure regulation
system must be securely
screwed to a stable
wall / ceiling (with 2 screws).
– Depending on the version, the
DuoComfort must be fitted to
a stable wall in a vertical pos-
ition or fitted to the top of the
gas cylinder box in a horizon-
tal position.
– Attention must be paid to the
installation position.
Protection against dirt / oil
A Truma gas filter must be in-
stalled in front of the gas press-
ure regulation system inlet in
order to reliably protect it against
dirt / oil. A set of operating and
installation instructions is sup-
plied with the gas filter.
17