Truma DuoComfort Mode D'emploi page 19

Masquer les pouces Voir aussi pour DuoComfort:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
The DuoComfort is intended for
installation in the gas cylinder box
of the caravan or motor home.
When it is being used outdoors,
the changeover valve must be
protected from the elements
and dripping water with a
protection hood, for example.
– Choose a suitable position for
the DuoComfort change over
valve, in particular:
– Type plate legible,
– Status indicator recognisable,
– Avoid damage during cylin-
der replacement,
– Make it difficult for gas in the
liquid phase to penetrate,
– Allow enough room to
retrofit the Truma remote
indicator,
– Route high-pressure hoses
without tension.
– Pull the retaining lug for the
blind cover over the outlet of
the changeover valve.
Duo Com fort
Figure 6
– Connect DuoComfort directly
to the gas pressure regulation
system. If necessary use
the Truma elbow union
(part. no. 50020-56000) or
the Truma additional kit
(part no. 50020-61100).
– Attach to the wall with two
screws.
– Screw high-pressure hoses to
the DuoComfort inlets, using
elbow unions (part. no. 50020-
56000) if necessary.
– After installation is complete,
leak-test the hose connection
at the changeover valve inlet
and the connection to the ad-
jacent gas pressure regulation
system (using, for example,
a leak finder spray complying
with DIN EN 14291).
This test does not replace
the regularly scheduled
gas check!
– All functions must then be
tested in accordance with the
operating instructions.
– The operating instructions
must be given to the operator.
19