Intended Use; Description; Type Key; Technical Characteristics - Samson NESE Manuel D'installation Et Mise En Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

  ENGLISH  
 
 
 
Lifting a pumpset : 
 
4
INTENDED USE 
NESE pumps are used to handle overheated water. 
The specific design of pump bearing bracket makes it possible to use a 
standard  mechanical  seal  and  avoid  the  use  of  an  expensive  auxiliary 
cooling device for the bearing bracket and the mechanical seal. 
Those  pumps  are  used  in  processes  whith  overheated  water  at  a 
nominal pressure of 40bars. 
 
5
DESCRIPTION 
5.1 TYPE KEY 
Pump  description  is  engraved  on  pump  name  plate.  It  gives  a 
 
general description of pump design. The nameplate is attached to 
pump bearing bracket. 
 
Description of a NESE pump is created as follows : 
 
Example : 
NESE50‐32‐160‐MCJ‐42‐T0,55/4K‐2D‐X 
NESE 
Pump product line 
50 
Nominal diameter of suction flange [mm] 
32 
Nominal diameter of discharge flange [mm]
160 
Nominal diameter of impeller [mm]  
Material used for casing and casing seal 
Mechanical seal type
Mechanical seal faces and O'Ring 
Ball bearing type 
Elastic coupling model for pump set 
Type of electric power supply 
0,55 
Installed power P
Number of pole 
Motor option 
2D 
ATEX option 
Specificity 
 
Detailed  technical  features  of  the  product  are  described  in 
acknowledgment  of  order  or  upon  request  to  SALMSON  Customer 
Department. 
 
5.2 TECHNICAL CHARACTERISTICS 
5.2.1
MATERIALS 
Material  
  Casing :  cast  iron  (EN‐GJS‐400‐18‐LT)  ‐  Sizes  65‐315,  80‐315  and  100‐
315 (cast steel GP240 GH) 
 Casing cover : cast iron (EN‐GJS‐400‐18‐LT) 
 Intermediate flange : cast iron (EN‐GJS‐400‐18‐LT) 
 Shaft: steel (X20Cr13 – AISI420) 
 Shaft sleeve : stainless steel (316Ti) 
[KW]
2
 
 Impeller : cast iron (EN‐GJL250) 
 Bearing housing : cast iron (EN‐GJS‐400‐18‐LT) 
 Bearing : SiC/SiC 
 
Sealing 
 Casing seal : graphite stainless steel reinforced flat gasket. 
 Shaft sealing : single balanced mechanical seal with unprotected spring 
SiC /Carbon /EPDM.
5.2.2
PERFORMANCE AND OPERATING LIMITS 
 
5. 2. 2. 1 TEMPERATURE 
NESE  pumps  are  designed  to  handle  overheated  water  from  170°C  to 
230°C.  Running  time  at  a  temperature  lower  than  170°C  should  be 
limited to the necessary time needed to reach working temperature. 
Thanks  to  the  bearing  bracket  design,  the  fluid  temperature  in  the 
mechanical seal chamber is limited to 220°C max. 
 
 
 
5. 2. 2. 2 PRESSURE 
Maximum  working  pressure  is  35bar  up  to  200°C  and  32bar  above 
200°C. 
 
Hydrostatic test pressure : 52bar 
 
Bearing  bracket  design  includes  a  prestressed  axial  thrust  bearing  (4 
point contact ball bearing) to bears heavy axial loads even at 2900RPM. 
 
 
Ensure a minimum pressure of 8 bars in the loop to ensure proper 
lubrication  of  the  internal  silicon  carbide  bearing  and  to  avoid 
degassing in MS chamber. 
 
contact  ball 
bearing
 
points 
 

Publicité