– In order to ensure that the Mover® operates
correctly, the gap between the tyres and the
disengaged drive rollers must be 20 mm.
All tyres must be inflated to the same
pressure in accordance with manufacturer's
instructions and checked regularly. Tyre
wear or the fitting of new tyres may make it
necessary to readjust the gap between the
drive rollers and the tyres (see "Fitting the
drive elements").
– When using a jack, the Mover® must not be
used as a jacking point as this may damage
the drive assembly.
– Sensitive objects such as cameras, DVD play-
ers etc. must not be kept in the stowage box
near the control unit or the motor cables,
as the powerful electromagnetic fields may
damage them.
– The empty weight of the vehicle increases by
the weight of the Mover®, which reduces the
payload of the vehicle.
– Remove the plug from the safety socket af-
ter manoeuvring, otherwise the battery will
be discharged. Quiescent current with plug
inserted approx. 200 mA. Quiescent current
with plug removed < 1 mA.

General instructions

The Mover® SE R was developed for negoti-
ating gradients of up to approximately 25 %
with a total weight of 1200 kg or 15 % with
a total weight of 2000 kg. The Mover® TE R
was developed for negotiating gradients of
up to approximately 25 % with a total weight
of 1200 kg or 10 % with a total weight of
2250 kg on a suitable surface.
Depending on the weight of the caravan, the
Mover® may not be able to overcome obstacles
more than about 3 cm in height without auxili-
ary equipment (please use ascent chocks).
As a result of the characteristic properties of a
radio signal, it may be interrupted by terrain /
objects. This reduces reception quality in small
areas around the caravan, as a result of which
the operation of the Mover® may be briefly
interrupted.
When the Mover® is switched off using
the remote control, the control unit re-
mains in standby. In order to switch off com-
pletely the battery must be disconnected or an
isolating switch installed.

Batteries

For optimum operation we recommend the Truma
Mover® PowerSet, which contains batteries with button cells
and an appropriate charger.
So-called drive, lighting and gel batteries with sufficient
capacity are also suitable.

Recommended battery capacities

Button cell technology
Gel / AGM
Lead-acid battery (liquid electrolyte)
Starter batteries are not suitable
Batteries with greater capacity allow the equipment to
be used for longer.

Charger

For optimum battery charging we recommend the Truma
BC 10 charger, which is suitable for all battery types up to
200 Ah.
Battery care
(including maintenance-free batteries)
In order to achieve a long battery service life, attention must
be paid to the following points:
– Batteries should be fully charged before and after removing
power,
– for stationary periods of longer than 24 hours, interrupt
power circuit (e.g. using circuit breaker or by disconnecting
the battery poles),
– for longer stop periods the battery must be disconnected
and charged for 24 hours at least every 12 weeks.
In winter, store fully charged battery in a cool and
frost-free place and recharge at regular intervals (every
12 weeks).

Function description

Always observe the operating instructions and the
"Safety instructions" prior to starting! The vehicle owner
is responsible for correct operation of the device.
Please note that the Mover® SE R is only suitable for
single-axle trailers, while the Mover® TE R is only suit-
able for dual-axle trailers.
The Mover® is a manoeuvring system which allows a caravan
to be manoeuvred without the aid of the towing vehicle.
It consists of two separate drive assemblies, each with its
own 12 V DC motor. These units are mounted on the frame
of the vehicle in the immediate vicinity of the wheels, and are
connected by lateral bars.
Once the drive rollers have been engaged on the tyres using
the remote control, the Mover® is ready for operation. It is
operated exclusively via the remote control, which transmits
radio signals to the control unit. A separately installed 12 V
lead-acid battery or suitable lead-gel battery (not supplied)
provides the control unit with electrical power.
at least 75 Ah
at least 90 Ah
at least 100 Ah
17