SECTION 3
3.3
Coolant Connections
These connectors are located on the back of the unit . Connect the hoses to the CC11 accordingly . The torch
hose ends should be fitted with one 5/8"18 male lefthand air / water hose and one 5/8"18 female righthand
air / water hose connector .
With the torch and the CC11 connected, fill the reservoir with the specially formulated torch coolant . Do not use
regular antifreeze solutions, such as for an automobile, as the additives will harm the pump and torch . ESAB P/N
0558004297 is recommended for service down to 12° F (11° C) . ESAB P/N 156F05 is recommended for service
below 12° F (11° C) to 34° F (36° C) .
Coolant Connections
After filling the reservoir, run the pump with its cap removed in order to purge air from the radiator, hoses, and
torch . Recheck coolant level to ensure reservoir is filled . Replace reservoir cap after purging and checking cool
ant level .
CAUTION
Do not connect hoses to a solenoid valve that can be closed when the
pump is operating as damage to pump can result.
65
INSTALLATION