CC-11 Front Panel Controls / Functions (con't.)
E. Pump Over Temperature Lamp:
If coolant flow through the CC­11 is substantially blocked, and the back pressure regulator fails to operate prop­
erly, the pump will temporarily be protected by its internal relief valve . After a few minutes of such operation,
however, the pump will reach temperatures which will cause it to fail . A thermal switch is mounted near the
pump which will sense an over temperature condition and shut the pump motor off before damage occurs . If
this thermal switch is activated, this lamp will also be lit .
F. F1 & F2:
Each of these fuses is on one leg of the 230 VAC supplied by the CC­11 to the fan and pump motors .