Pump Installation - Pentair BERKELEY BPD Serie Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
Figure 8 – Bolt Pump Down
Figure 9 – Independently Support All
Piping Attached to Pump
Use PTFE pipe thread sealant tape or pipe joint
compound approved for use on PVC.
No air leaks In
Suction pipe.
If air flows
water won't
Use PTFE tape.
Figure 10 – Use PTFE pipe thread sealant tape on pipe
joints and connections to pump.
Do not use in a pressure tank or booster pump application.

PUMP INSTALLATION

NOTICE: Use only PTFE pipe thread sealant tape for making all threaded
connections to the pump itself. Do not use pipe joint compounds on
plastic pumps: they can react with the plastic in the pump components.
Make sure that all pipe joints in the suction pipe are air tight as well as
water tight. If the suction pipe can suck air, the pump will not be able to
pull water from the well.
532 1193
1. Bolt pump to solid, level foundation.
2. Support all piping connected to the pump.
3. Wrap 1-1/2 to two layers of PTFE pipe thread sealant tape clockwise (as
you face end of pipe) on all male threads being attached to pump.
4. Tighten joints hand tight plus 1-1/2 turns. Do not overtighten.
NOTICE: Install pump as close to well head as poss ible. Long piping runs
and many fittings create friction and reduce flow.
NOTICE: For long horizontal pipe runs, install a priming tee between
check valve and well head as shown in Figure 6. For driven point
installations, install a check valve as shown in Figure 6. Be sure check
530 1193
valve flow arrow points toward pump.
Use schedule 80 or iron pipe. See "Well Pipe In stalla tion" for more
information.
Don't Hit
Thread Stops
Pump
From
Body
Well
Hand Tight Plus 1-1/2 Turns With Wrench.
Figure 11 – Don't overtighten.
6
Don't
Overtighten
748 0993