Pentair BERKELEY BPD Serie Notice D'utilisation page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical
Motor
Model
HP
BPDH10-L
1
BPDH15-L
1-1/2
BPDH20-L
2
BPDH25-L
2-1/2
1. Install, ground, wire and maintain this pump in accordance with
electrical code requirements. Consult your local building inspector for
information about codes.
2. Provide a correctly fused disconnect switch for protection while
working on motor. Consult local or national electrical codes for switch
requirements.
3. Disconnect power before servicing motor or pump. If the disconnect
switch is out of sight of pump, lock it open and tag it to prevent
unexpected power appli cation.
4. Ground the pump permanently using a wire of the same size as that
specified in wiring chart (below). Make ground connection to green
grounding term inal under motor canopy marked GRD. or
5. Connect ground wire to a grounded lead in the service panel or to a
metal underground water pipe or well casing at least 10 feet long. Do
not connect to plastic pipe or insulated fittings.
6. Protect current carrying and grounding conductors from cuts, grease,
heat, oil, and chemicals.
7. Connect current carrying conductors to terminals L1 and L2 under
motor canopy. When replacing motor, check wiring diagram on motor
nameplate against Figure 12. If the motor wiring diagram does not
match either diagram in Figure 12, follow the dia gram on the motor.
IMPORTANT: 115/230 Volt single phase models are shipped from factory
with motor wired for 230 volts. If power supply is 115 volts, remove motor
canopy and reconnect motor as shown in Figure 12. Do not try to run
motor as received on 115 volt current.
8. Motor has automatic internal thermal overload protection. If motor has
stopped for unknown reasons, thermal overload may restart it unex-
pectedly, which could cause injury or property damage. Disconnect
power before servicing motor.
9. If this procedure or the wiring diagrams are con fusing, consult a
licensed electrician.
Wiring Chart – Recommended Wire and Fuse Sizes
Branch
Max.
Fuse
Load
Rating
Volts
Amp
Amp
115/230 14.8/7.4
20/15
115/230 19.2/9.6
25/15
115/230 24.0/12.0
30/15
115/230 26.0/12.0
30/15
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 ­ 100
101 ­ 200
(0 ­ 30)
(31 ­ 61)
AWG WIRE SIZE (mm
12/14(3/2)
8/14(8.4/2)
10/14(5.5/2)
8/14(8.4/2)
10/14(5.5/2)
6/14(14/2)
8/14(8.4/2)
6/14(14/2)
201 ­ 300
301 ­ 400
(62 ­ 91)
(92 ­ 122)
)
2
6/14(14/2)
6/12(4/3)
6/12(14/3)
4/10(21/5.5)
6/12(14/3)
4/10(21/5.5)
6/12(14/3)
4/10(21/5.5)
8
.
401 ­ 500
(123 ­ 152)
4/10(21/5.5)
4/10(21/5.5)
4/10(21/5.5)
4/10(21/5.5)