Submersible Pump; Pump Installation - Pentair STA-RITE 10DOM05121 Manuel D'utilisation

Masquer les pouces Voir aussi pour STA-RITE 10DOM05121:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation/Operation
Submersible
Figure 1: Insert a 3" PVC pipe in the bottom of the
motor to raise the pump in the tank.

PUMP INSTALLATION

Risk of electrical shock. Do not remove or alter
cord. Do not connect conduit to pump.
1. Only qualified personnel should install the pump and asso-
ciated control equipment.
2. Vent sewage tank according to local code.
3. Do not install pump in any location classified as hazard-
ous by National Electrical Code, ANSI/NFPA 70-1984.
Table 1: Recommended Fusing Data
60 Hz/1 Phase 2-Wire Cable
Pump Model
Motor HP
10DOM05121
20DOM05121+1
30DOM05121
10DOM05221
20DOM05221+1
30DOM05221
10DOM07221
20DOM07221
30DOM07221
10DOM10221
20DOM10221
30DOM10221
Pump
3" pipe
4134 0202
Volts
0.5
115
0.5
115
0.5
115
0.5
230
0.5
230
0.5
230
0.75
230
0.75
230
0.75
230
1
230
1
230
1
230
4. These pumps are intended for permanent connection only.
Provide strain relief at control panel for power supply
cord connection to box. All control components must be
UL listed and suitable for end use application.
5. Do not pump flammable liquids, strong caustics, or strong
acids with this pump.
6. To prevent dropping pump, lower it by the drop pipe, not
by the cables. The electrical cables will not hold the pump
weight.
7. Discharge outlet is 1-1/4" NPT threaded.
NOTICE: If installing external check valve, hold discharge
with pipe wrench to prevent loosening discharge in shell.
8. If pump is to be operated with an open discharge, a dis-
charge valve must be installed. Before startup, open this
valve about 1/3 open. Start pump. Slowly open valve until
the desired flow rate is reached. Final setting must be with-
in pump's recommended operating range.
OPERATION
1. The pump must be submerged at all times during normal
operation. Do not run pump dry.
2. Make sure that the float switches are set so that the pump
stops before the pump runs dry or breaks suction. If neces-
sary, adjust float switches to achieve this.
3. The motor bearings are lubricated internally. No mainte-
nance is required or possible on the pump.
Max. Load
Locked Rotor
Amp
Amps
11
25
10.6
25
9.5
23
5.5
14.8
5.3
14.8
4.6
12
7.3
27.7
6.5
27.7
5.6
14.8
9.6
41.3
7.7
35.7
7
20.4
Fast Acting
Slow Acting
Fuse
Fuse
20
15
20
15
20
15
10
10
10
10
10
10
15
10
15
10
15
10
20
15
15
10
15
10
3
Circuit
Breaker
20
20
15
10
10
10
15
10
10
15
15
15

Publicité

Table des Matières
loading

Table des Matières