Connecting To 115 Volts Ac Duplex Receptacle; Electrical Service Guide - Miller CP-302 Manuel D'utilisation

Masquer les pouces Voir aussi pour CP-302:
Table des Matières

Publicité

2-12. Connecting To 115 Volts AC Duplex Receptacle

3
2
1

2-13. Electrical Service Guide

60 Hertz Models
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Am-
1
peres
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet
(Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
200
34.5
2
Time-Delay
Normal Operating 3
116 (35)
50 Hertz Models
1
250 Amp Model
230
460
30
15
40
35
15
50
45
20
8
10
14
100 (31)
157 (48)
105 (32)
10
10
14
220
34.5
2
Time-Delay
40
Normal Operating 3
50
8
127
(39)
10
1
115 V 15 A AC Receptacle
RC9
Power is shared between RC9 and
remote 14 receptacle RC8.
2
Circuit Breaker CB1
3
Circuit Breaker CB2
CB1 protects 115 volts ac portion of
RC8 and RC9 from overload.
CB2 protects 24 volts ac portion of
RC8 from overload.
Press button to reset breaker.
Ref. ST-801 380-B
300 Amp Model
200
230
460
38
33
16.5
45
40
20
60
50
25
8
8
12
139 (42)
221 (67)
223 (68)
10
10
12
300 Amp Model
380
400
440
20
19
17.3
25
20
20
30
30
25
12
12
12
151
167
202
(46)
(51)
(62)
12
12
12
OM-259 Page 17
575
13
15
20
14
14
520
14.6
15
20
14
183
(56)
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cp-252ts

Table des Matières