INSTALLATION
SPECIFICATION
17.4 Technical Data
Model
Type
Part number
Version
Operating details
Lower application limit for heat pump operation (air temperature)
Upper application limit for heat pump operation (air temperature)
Hot water temperature, heat pump
Hot water temperature, booster heater
Air flow rate
Tank capacity
Refrigerant
Refrigerant / filling weight
Water heater height (minimum)
Water heater height (maximum)
Water heater diameter
Dimension when tilted incl. packaging
Dimension when tilted, excl. top packaging
Dimension when tilted, excl. wooden pallet and top packaging
Dimension when tilted, excl. packaging
Weight (dry tank)
Weight (wet)
Water connection with adaptor
Condensate drain
Condenser
Permissible operating pressure, low (cold) side*
Permissible positive pressure, high (hot) side*
Sound pressure level (spl)
Maximum inlet water temperature
Electrical details
Power connection, voltage / frequency
Protection
Maximum power consumption (Tamb = 42 °C (108 °F),
Twater = 60 °C (140 °F), 240 V)
Required circuit breaker size
Rated power consumption, heat pump
Rated power consumption HP (in accordance with DIN 8947, at 15 °C (59 °F) air
temperature, 70% RH and 45 °C (113 °F)water temperature)
Power consumption, booster heater
Heating output HP (at 15 °C (59 °F) air temperature, 70% RH, water heat-up from
15 °C (59 °F) to 60 °C (140 °F), in accordance with EN 255 T3, 240 V / 60 Hz)
WWW.STIEBEL-ELTRON-USA.COM
With passive defrosting and booster heater
Rollbond safety heat exchanger
L1,L2,G / 208-240
ACCELERA® 300 HEAT PUMP WATER HEATER |
Accelera 300
Heat pump water heater
222423
42.8 °F / 6 °C
107 °F / 42 °C
140 °F / 60 °C
140 °F / 60 °C
324 cfm / 550 m
3
/h
80 gal / 303 l
R 134a
32 oz / 900 g
73.4� / 1865 mm
74.9� / 1903 mm
26� / 660 mm
87.6� / 2225 mm
84.7� / 2150 mm
79.9� / 2030 mm
78.4� / 1990 mm
287 lbs / 130 kg
950 lbs / 432 kg
Union to 3/4"
3/4"
87 psi / 0.6 MPa
348 psi / 2.4 MPa
55.2 dB(A)
140 °F / 60 °C
/ 60/50
V
Hz
IP 24
2.2 kW
15 A double pole breaker
2.5 A
0.5 kW
1.690 kW
approx. 1.7 kW
29