INSTALLATION
INSTALLATION
» Remove the packaging straps.
» Push the packaging foil far enough upwards that the pallet is
freely accessible.
» Remove the water heater carefully with the polystyrene
packaging from the pallet.
DANGER Injury from tipping over
The water heater has a high centre of gravity and a
low overturning moment. Ensure that the water heater
does not overturn when you remove it from its pallet.
» Slide the packaging foil far enough upwards to be able to
remove the first polystyrene
polystyrene
profiles on the sides are used as installation
®
aids in the following steps.
» Separate the lower packaging section at the dividing line.
For this, make an incision of approx. 30 mm (1.25") into both
sides of the dividing line.
WWW.STIEBEL-ELTRON-USA.COM
®
profiles from the sides. These
®
» Slightly tilt the water heater.
DANGER Injury from overturning
Secure the water heater against overturning by
getting a second person to support the water heater.
» Push a wooden support underneath the lower part of the
packaging.
» Break out the free semi-shell of the lower section of the
packaging.
» Keep the water heaters slightly tilted.
» Wind out the free leveling foot, but not by more than 30 mm
(1.25").
» Turn the locking nut on the thread of the leveling foot
towards the bottom cover. When the locking nut is tight
against the bottom cover, it stabilizes the leveling foot.