CONNECTER ENTRE LE
PIN M6.1 & M6.2 DE LA
CARTE DE
CONNEXION LA
SONDE SANITAIRE
LE
PREMIER DIGIT
AFFICHE
5-XX
OUI
POMPE EN
FONCTION
NON
230 Vac
ENTRE LES
TERMINAUX X1.P
& X1.N SUR LA
MCBA
OUI
TENSION
SUR LA POMPE
NON
SUBSTITUER
CÂBLAGE OU
CONNEXIONS
64
DEBUT
DECONNECTER SONDE
NTC3 OU THERMOSTAT
EAU SANITAIRE
ALLUMER LA
CHAUDIÈRE
ATTENDRE LA FIN
DU CYCLE DE START
UP
LE
PREMIER DIGIT
OUI
AFFICHE
0-XX
NON
CONTRÔLER LE
CYCLE DE START UP
(TEST A)
NON
OUI
C1
NON
SUBSTITUER
CARTE MCBA
SUBSTITUER
CARTE MCBA
OUI
SUBSTITUER
POMPE
SUBSTITUER
CARTE DE
CONNEXION
TEST C : TEST DE L'APPAREIL DE
CONTRÔLE EN PHASE SANITAIRE
CONTRÔLER
NTC3 OU LES CONNEXIONS
THERMOSTAT SANIT.
2-4 VDc
ENTRE LES
TERMINAUX
OUI
X3.3 & X3.5
SUR LA CARTE
MCBA
NON
2-4 Vdc
ENTRE LES
TERMINAUX M 6.1
& M 6.2 SUR LA
OUI
CARTE DE
CONNEXION
NON
2-4 Vdc
ENTRE LES
TERMINAUX M5.4 & M5.5
SUR LA CARTE DE
CONNEXION
CONTRÔLER ET/OU
SUBSTITUER
CÂBLAGE OU
NON
CONNEXIONS
CONTRÔLER
CONNEXIONS
THERMOSTAT OU
SONDE SANITAIRE
A LA CHAUDIÈRE
OUI