TROUBLESHOOTING MOTOR
Problem
The blade does not stop
within 10 seconds after
releasing the power switch.
The motor will not start.
Heavy sparking from the
carbon brushes when the
power switch is released.
78
Possible cause
The carbon brush cover is
not closed or the brushes are
jamming.
The spindle screw has come
loose.
Other.
Fuse has tripped.
The carbon brushes are worn.
Other.
The carbon brushes are worn.
Action
Check and clean, or replace
the carbon brushes. More
detailed instructions can be
found in the section on care
and maintenance.
Tighten the spindle screw.
Contact the retailer.
Check and replace, or reset
the fuse. Use a
10 A slow fuse.
Replace the carbon brushes.
More detailed instructions
can be found in the section on
care and maintenance.
Contact the retailer.
Replace the carbon brushes.