14
Installation
Dimensions minimales de cadrage
HINT: place the fireplace so the center
line is at least 5" (127mm) from both
vertical framing members at the rear (this
allows the vent to pass through the
framing without modfications)
Minimum 38" (965mm)
Fireplace Enclosure Height
Route the
electrical line to
a position to the
left rear of the
fireplace.
© Travis Industries
(pour des installateurs qualifiés seulement)
Included Firestop (required)
33-1/2"
851mm
36-1/2"
927mm
4131120
Part # 250-00747
Vent Clearances for 8" (203mm) dia. Vent:
1" (25mm) to the sides, 1" (25mm) below,
and 4" (102mm) above the vent to
combustibles.
Center of Rear Vent
24-1/4"
616mm
32-1/2"
826mm
19-1/4"
489mm
16-1/2"
419mm
The on/off switch/thermostat wire (if
used) should be routed to a location
near the right front of the fireplace.
100-01364_FR