1 Safety

1.1 Instructions for Safe Operation

² Check the main unit and all accessories periodically to make sure that there is no visible
damage that may affect patient's safety and monitoring performance. It is recommended that
the device should be inspected weekly at least. When there is obvious damage,stop using the
device.
² Necessary maintenance must be performed by qualified service engineers ONLY. Users are
not permitted to maintain it by themselves.
² If the battery has to be replaced, the battery shall be provided by manufacture and replaced
only by trained service personnel.Incorrect replacement and model of battery may cause
device damage and patient injury.
² The device can't be used together with devices not specified in User Manual.Only the
accessory that is appointed or recommendatory by manufacture can be used with this device.
² This product is calibrated before leaving factory.
² Users should have basic text distinguish ability.
² The patient is also an intended operator.Patient can use the device for measurement, storage
and data upload. While device maintenance, clean or batteries replacement is not allowed.
² During normal use , please do not position this device to make it difficult to disconnect form
power supply.
² After use,please switch off and unplug the device.

1.2 Warning

M Don't open the enclosure of the device to avoid tip-and-run danger.Necessary maintenance
and upgrade must be performed by qualified service engineers who have been trained and
accredited by our company ONLY
M Explosive hazard—DO NOT use the device in the environment with tinder such as
anesthetic .
M DO NOT use the device while the patient is being scanned by MRI or CT.
M The disposal of scrap instrument and its accessories and packing (including battery, plastic
bags, foams and paper boxes) should follow the local laws and regulations,and place them in
the place where the children can't reach.
M Please check the packing before use to make sure the device and accessories are totally in
accordance with the packing list, or else the device may have the possibility of working
abnormally.
M Please choose the accessories and probe which are approved or manufactured by the
manufacturer, or else it may damage the device.
M The device can only be matched with the compatible probe.
M Please don't measure this device with functional tester for the device's related information.
M Parts of this device are not allowed to be serviced or maintained while in use with the patient.

1.3 Attention

% Keep the device away from dust, vibration, corrosive substances, tinder, high temperature and
moisture.
% If the device gets wet, please stop operating it.