m The fog from the unit's outlet is very hot and
can cause the hose to melt if the device is not
used properly. In order to avoid heat from
building up directly behind the opening where
the fog emerges please ensure that there are
no kinks in the first meter of hose and that the
hose runs in a straight line from the unit!
5.2. Operating the unit
• Be sure to follow the advice for emergency power ge-
nerators (see item 2.3.)!
• The mains plug (10) must be connected to a Schuko
socket (230 V/50 Hz).
• A dot will appear in the bottom right-hand corner of the
plastic foil keypad (0).
• Press "ON" to power on the unit. The blower fan will
run in idle.
• The green LEDs light up to indicate that fog generator
is ready to use after approx. 7 min (warm-up phase).
• Press the + and – keys to select air and fog volume
settings from 1 – 10.
5.3. Powering off
• Switch the device to fog volume setting "0" at the end
of the procedure and allow to cool off for 5 minutes.
The induced ventilation (at air volume setting "0") is
perfectly sufficient.
• Press "OFF" to switch off the device.
• Remove the plug from the mains socket.
m Do NOT switch the unit off and do NOT disconnect
the unit from the mains power supply imme-
diately after use!
The generator needs to cool down for at least
5 minutes after each use! The remains of the
fog fluid are removed from the burning chamber
during this pressure cooling phase in order
to prevent any condensation damage from
occurring.
B -
3
06. Cleaning and Maintenance
6.1. Cleaning and maintenance
• The blue filter mats (9) must be cleaned and re-
placed when necessary. This depends on the level
of contamination and the amount of wear and tear
that they have been subjected to.
• Please make sure that the fog device does not run
without fluid. This can seriously damage the pump.
m Use original FS-100 fog fluid from TROTEC
• Turn the condensate drain plug (3) to drain off any
condensate that many have formed around the fog
exit opening (1).
• Use solvent-free cleaning agents only.
6.2. Storage
• The FS 100 can be stored in the optionally available
carry case.
• Be sure to select a safe and dry storage place, espe-
cially when storing over longer periods.
• Keep out of the reach of children! Make sure that the
fog device is stored in a safe place!
operating manual – Fog and smoke gas simulator
only. Other fluids, including non-approved fluids
like those used in discotheques for example,
can contain a higher proportion of water
which can cause sooting in the burning
chamber, which in turn can severely damage
your product!
en