Table of Contents
01. Scope of Delivery . . . . . . . . . . . . . . . . . . . B - 01
02. Safety Notes . . . . . . . . . . . . . . . . . . . . . . . B - 01
04. Fog Fluid . . . . . . . . . . . . . . . . . . . . . . . . . B - 02
08. Technical Data . . . . . . . . . . . . . . . . . . . . . B - 04
This publication replaces all previous publications. No part of this publication may
be reproduced, processed using electronic systems, replicated or distributed in any
way without prior written authorisation by us. Subject to technical modifications. All
rights reserved. Names of goods are used without guarantee of free usage and used
for the most part according to the manufacturers' syntax. The names of goods used
are registered and should be considered as such. We reserve the right to modify the
design in the interest of ongoing product improvement, such as shape and colour
modifications. The scope of delivery may vary from that in the product description. All
due care has been taken in compiling this document. We accept no liability for errors
or omissions. © TROTEC®
01. Scope of Delivery
1.1 Accessories included in the scope of delivery
• 6 m of fog hose (synthetic material DN 50) with1 x
Storz connector © and 1 x filling spout.
• 5-litre canister of fog fluid.
1.2. Optional accessories
• Robust carry case designed especially for the FS 100.
• Combustor and coloured smoke cartridges for fire
simulations.
• Additional 5-litre canister of fog fluid.
• Telescopic guide rod (up to 6 m) with quick-locking
device.
02. Safety Notes
2.1. General information
• Fog can activate smoke detectors!
• Do not drink or swallow the fog fluid! Keep out of
reach of children!
• Do not open any unit that is connected to a mains
supply and do not leave unsupervised!
B -
1
2.2. Instructions when using the FS 100
• The device may NOT be placed in a location that is
either flammable, combustible or heat sensitive.
• The unit may only be placed on a firm and even
surface that is large enough to support the device.
• A distance of at least 1 metre must be kept to any
flammable or heat-sensitive object.
• Glycols are alcohols, which is why the flame they
produce is light bluish and almost invisible to the
naked eye. NEVER allow fog to come into contact
with ignition sources like open fires, for example!
• Hot steam comes out of the fog opening! Danger!
Risk of burns!
• NEVER touch or go near the fog exit opening when
the simulator is in operation!
• Sometimes very hot fluid droplets can be dischar-
ged from the fog exit opening when the device is in
operation. Warning! Keep a safe distance of at least
3 metres to the unit!
2.3. Important information when using emergency
• Any emergency power units (EPUs) that you wish to
connect to the device must have a nominal output of
at least 2 kVA (230 V) and should be checked prior to
putting the simulator into operation to ensure that
they are in perfect working condition.
• The emergency power unit must be brought to ope-
rating temperature free of any load for approx. 1 - 2
minutes (depending on the EPU) before the fog simu-
lator is connected.
• Only then will the fog simulator operate as it was
designed to do.
operating manual - Fog and smoke gas simulator
power units