07. Troubleshooting
Faults
Possible Causes
The FS 100 fails to
Check power supply and
produce fog.
make sure that the device is
properly connected.
Check the filling level of the
fog fluid.
Check to make sure that the
canister is leak tight.
Check the Sinter filter for
contamination.
The device makes
The pump is running dry.
loud humming
Please avoid at all costs!
noises when fog is
Fill up with fog fluid.
being produced.
Check hose connections
and make sure that they are
locked in place.
08. Technical Details
Dimensions (LxWxH)
Weight (incl. 5 l fluid)
Supply voltage
Compressor output power
Fan turbine output power
Input power max
IP-rating
Air flow rate
Fluid amount in canister
Fluid consumption at max.
throughput
Permanent fog
Fog time at Setting 10
Setting 5 and lower
Warm-up time
en
560 x 295 x 350 mm
21,5 kg
230 V / 50 Hz
1.200 W
1.200 W
2.400 W
IP44
approx. 50 l/s
5 l
120 ml/min
35 ml/min
approx. 40 s
permanent fog
approx. 7 min
operating manual – Fog and smoke gas simulator
09. Certificate of Non-Objection
Certificate of non-objection for the fog fluid "Fog
Fluid FS 100"
This is to certify that our fog fluid FL-FS 100 does not
present a hazardous working material in accordance
with §§ 3/3a Chemical Law of 16.09.1980, with mo-
difications made on 14.03.1990, Text Edition of BGBl.
(German Civil Code), 1/1990, page 522. (The modifi-
cation of Annex 1 of 05.06.1991, BGBl. 1, page 1219,
is incorporated.)
These components are not listed in the List of Main
Substances as stated in the Version of Annex VI of
the Ordinance for Hazardous Substances (Date:
26.08.1986, BGBl 1, page 1470, in the version of the
third legal ordinance for modifications of the Ordi-
nance for Hazardous Substances of 05.06.1991, BGBl.
1, page 1218). It was not assigned an MPC-value
(Maximum Permissible Concentration) according to
the IRGS 900 (Regulations for Dangerous Materials) of
the Ordinance for Hazardous Substances (MPC-Value
List 1991). It does not present a health hazard when
used properly and for the purpose for which it was
intended. The fluid is not flammable according to the
Ordinance for Hazardous Substances Part 4, Chapter
4.1. The product is water soluble and bio-degradable.
B - 4